The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Volumetric Absorptive Microsampling: A Dried Sample Collection Technique for Quantitative Bioanalysis
Abstract
Volumetric absorptive microsampling (VAMS) is a novel approach to obtaining a dried blood sample for quantitative bioanalysis that overcomes the area bias and homogeneity issues associated with conventional dried blood spot (DBS) sample when a subpunch is taken. The VAMS sampler absorbs a fixed volume of blood (∼10 μL) in 2-4 s with less than 5% volume variation across the hematocrit range of 20-70% with low tip-to-tip variability. There is no evidence of selective absorption by the tip of the plasma component over whole blood. Recommendations for best practice when collecting samples were developed based upon the results of tests examining a number of potential abuse scenarios.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Drabkin, D. L., & Austin, J. H. (1932) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)76122-x · Cited by 766
Use of Filter Paper for the Collection and Analysis of Human Whole Blood Specimens
Mei, J. V., Alexander, J. R., Adam, B. W., & Hannon, W. H. (2001) · The Journal of Nutrition · doi:10.1093/jn/131.5.1631s · Cited by 579
Barfield, M., Spooner, N., Lad, R., Parry, S., & Fowles, S. (2008) · Journal of Chromatography B · doi:10.1016/j.jchromb.2008.05.025 · Cited by 273
Self-citationCapiau, S., Stove, V. V., Lambert, W. E., & Stove, C. P. (2012) · Analytical Chemistry · doi:10.1021/ac303014b · Cited by 157
State-Of-The-Art Dried Blood Spot Analysis: an Overview of Recent Advances and Future Trends
Meesters, R. J. W., & Hooff, G. P. (2013) · Bioanalysis · doi:10.4155/bio.13.175 · Cited by 125
The introduction of newborn screening for phenylketonuria
Guthrie, R., & Bickel, H. (1996) · European Journal of Pediatrics · doi:10.1007/pl00014247 · Cited by 59
Chao, T. C., Trybała, A., Starov, V. M., et al. (2014) · Colloids and Surfaces A Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2014.03.033 · Cited by 53
Chen, P.-W., Lee, N., Chien, Y., Wu, J., Wang, P.-C., & Hwu, W. (2014) · Clinica Chimica Acta · doi:10.1016/j.cca.2014.01.034 · Cited by 37
Cited by
Digitally Enabled, Patient‐Centric Clinical Trials: Shifting the Drug Development Paradigm
Dockendorf, M. F., Hansen, B. J., Bateman, K. P., Moyer, M., Shah, J. K., & Shipley, L. A. (2021) · Clinical and Translational Science · doi:10.1111/cts.12910 · Cited by 67
van den Broek, I., Fu, Q., Kushon, S., Kowalski, M. P., Millis, K., Percy, A., Holewinski, R. J., Venkatraman, V., & Van Eyk, J. E. (2017) · Clinical Mass Spectrometry · doi:10.1016/j.clinms.2017.08.004 · Cited by 62
Metadata
- Authors
- Denniff, P., & Spooner, N.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-08-06
- Volume
- 86
- Issue
- 16
- Pages
- 8489-8495
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2318583543
- Cited by
- 396
- References
- 8
- FWCI
- 11.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Volumetric Absorptive Microsampling: A Dried Sample Collection Technique for Quantitative Bioanalysis. https://app.cochat.ai/papers/10.1021/ac5022562
- The paper
- Denniff, P., & Spooner, N. (2014). Volumetric Absorptive Microsampling: A Dried Sample Collection Technique for Quantitative Bioanalysis. Analytical Chemistry. https://doi.org/10.1021/ac5022562
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.