The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Reagentless, Ratiometric Electrochemical DNA Sensors with Improved Robustness and Reproducibility
Open accessAbstract
To make the electrochemical DNA sensors (E-sensor) more robust and reproducible, we have now for the first time adapted the techniques of ratiometric analyses to the field of E-sensors. We did this via the simple expedient way of simultaneously using two redox probes: Methylene blue as the reporter of the conformational change, and ferrocene as an internal control. During the conformational transduction, only the distance between the signal probe and the electrode surface undergoes an appreciable change, while the distance between the control probe and the electrode remains relatively constant. This special design has allowed very reliable target recognition, as illustrated in this report using a human T-lymphotropic virus type I gene fragment. The standard deviation between measurements obtained using different electrodes was an order of magnitude less than that obtained using a classic E-sensor, which we prepared as a control. A limit of detection of 25.1 pM was obtained with our new system, with a single mismatch discrimination factor of 2.33 likewise being observed. Additionally, this concept had general applicability, and preliminary data of a "Signal-On" ratiometric E-sensor are also provided. Taken in concert, these results serve to validate the utility of what we believe will emerge as an easily generalized approach to oligonucleotide recognition and sensing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Drummond, T. G., Hill, M. G., & Barton, J. K. (2003) · Nature Biotechnology · doi:10.1038/nbt873 · Cited by 2,214
Predicting DNA duplex stability from the base sequence
Breslauer, K. J., Frank, R., Blöcker, H., & Marky, L. A. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.11.3746 · Cited by 1,837
Cited by
Electrochemical Sensors and Biosensors Based on Nanomaterials and Nanostructures
Zhu, C., Yang, G., Li, H., Du, D., & Lin, Y. (2015) · Analytical Chemistry · doi:10.1021/ac5039863 · Cited by 1,741
Nucleic Acid Biosensors: Recent Advances and Perspectives
Du, Y., & Dong, S. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04190 · Cited by 429
Self-citationChen, T., Li, M., & Liu, J. (2018) · Crystal Growth & Design · doi:10.1021/acs.cgd.7b01503 · Cited by 350
Li, S., Zhang, H., Zhu, M., Kuang, Z., Li, X., Xu, F., Miao, S., Zhang, Z., Lou, X., Li, H., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00759 · Cited by 309
Metadata
- Authors
- Du, Y., Lim, B. J., Li, B., Jiang, Y. S., Sessler, J. L., & Ellington, A. D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-07-18
- Volume
- 86
- Issue
- 15
- Pages
- 8010-8016
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2313612068
- Cited by
- 182
- References
- 2
- FWCI
- 7.42
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reagentless, Ratiometric Electrochemical DNA Sensors with Improved Robustness and Reproducibility. https://app.cochat.ai/papers/10.1021/ac5025254
- The paper
- Du, Y., Lim, B. J., Li, B., Jiang, Y. S., Sessler, J. L., & Ellington, A. D. (2014). Reagentless, Ratiometric Electrochemical DNA Sensors with Improved Robustness and Reproducibility. Analytical Chemistry. https://doi.org/10.1021/ac5025254
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.