The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Direct Detection of DNA below ppb Level Based on Thionin-Functionalized Layered MoS2 Electrochemical Sensors
Abstract
A layered MoS2-thionin composite was prepared by sonicating their mixture in an ionic liquid and gradient centrifugation. Because DNA is rarely present in single-stranded form, either naturally or after PCR amplification, the composite was used for fabrication of a double-stranded DNA (dsDNA) electrochemical biosensor due to stable electrochemical response, intercalation, and electrostatic interaction of thionin with DNA. The linear range over dsDNA concentration from 0.09 ng mL(-1) to 1.9 ng mL(-1) is obtained, and moreover, it is suitable for the detection of single-stranded DNA (ssDNA). The biosensor has been applied to the detection of circulating DNA from healthy human serum, and satisfactory results have been obtained. The constructed DNA electrochemical biosensor shows potential application in the fields of bioanalysis and clinic diagnosis. Furthermore, this work proposes a new method to construct electrochemical biosensors based on MoS2 sheets.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomimetic Hydrogen Evolution: MoS 2 Nanoparticles as Catalyst for Hydrogen Evolution
Hinnemann, B., Moses, P. G., Bonde, J., Jørgensen, K. P., Nielsen, J. H., Horch, S., Chorkendorff, I., & Nørskov, J. K. (2005) · Journal of the American Chemical Society · doi:10.1021/ja0504690 · Cited by 4,065
Drummond, T. G., Hill, M. G., & Barton, J. K. (2003) · Nature Biotechnology · doi:10.1038/nbt873 · Cited by 2,214
Laursen, A. B., Kegnæs, S., Dahl, S., & Chorkendorff, I. (2012) · Energy & Environmental Science · doi:10.1039/c2ee02618j · Cited by 1,348
Wang, T., Liu, L., Zhu, Z., Papakonstantinou, P., Hu, J., Liu, H., & Li, M. (2013) · Energy Environ. Sci. · doi:10.1039/c2ee23513g · Cited by 393
Self-citation
Cited by
Electrically-Transduced Chemical Sensors Based on Two-Dimensional Nanomaterials
Meng, Z., Stolz, R. M., Mendecki, L., & Mirica, K. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00311 · Cited by 773
Two-dimensional materials in biomedical, biosensing and sensing applications
Rohaizad, N., Mayorga-Martinez, C. C., Fojtů, M., Latiff, N. M., & Pumera, M. (2021) · Chemical Society Reviews · doi:10.1039/d0cs00150c · Cited by 506
Wang, H., Li, C., Fang, P., Zhang, Z., & Zhang, J. Z. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00314a · Cited by 430
Samadi, M., Sarikhani, N., Zirak, M., Zhang, H., Zhang, H.-L., & Moshfegh, A. Z. (2018) · Nanoscale Horizons · doi:10.1039/c7nh00137a · Cited by 408
Two‐Dimensional Transition Metal Dichalcogenides in Biosystems
Kalantar‐zadeh, K., Ou, J. Z., Daeneke, T., Strano, M. S., Pumera, M., & Gras, S. L. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201500891 · Cited by 371
Recent advances in transition-metal dichalcogenides based electrochemical biosensors: A review
Wang, Y.-H., Huang, K.-J., & Wu, X. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.06.011 · Cited by 358
Biosensors Based on Two-Dimensional MoS2
Kalantar-zadeh, K., & Ou, J. Z. (2016) · ACS Sensors · doi:10.1021/acssensors.5b00142 · Cited by 357
Li, S., Zhang, H., Zhu, M., Kuang, Z., Li, X., Xu, F., Miao, S., Zhang, Z., Lou, X., Li, H., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00759 · Cited by 309
Nanostructured MoS2-Based Advanced Biosensors: A Review
Barua, S., Dutta, H. S., Gogoi, S., Devi, R., & Khan, R. (2018) · ACS Applied Nano Materials · doi:10.1021/acsanm.7b00157 · Cited by 306
Li, X., Shan, J., Zhang, W., Su, S., Yuwen, L., & Wang, L. (2017) · Small · doi:10.1002/smll.201602660 · Cited by 301
Ping, J., Fan, Z., Sindoro, M., Ying, Y., & Zhang, H. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201605817 · Cited by 294
Joseph, S., Mohan, J., Lakshmy, S., Thomas, S., Chakraborty, B., Thomas, S., & Kalarikkal, N. (2023) · Materials Chemistry and Physics · doi:10.1016/j.matchemphys.2023.127332 · Cited by 284
Graphene-like 2D nanomaterial-based biointerfaces for biosensing applications
Zhu, C., Du, D., & Lin, Y. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.06.045 · Cited by 270
Low‐Dimensional Transition Metal Dichalcogenide Nanostructures Based Sensors
Li, B. L., Wang, J., Zou, H. L., Garaj, S., Lim, C. T., Xie, J., Li, N. B., & Leong, D. T. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201602136 · Cited by 269
Bertolazzi, S., Gobbi, M., Zhao, Y., Backes, C., & Samorì, P. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00169c · Cited by 269
Graphene-like two-dimensional layered nanomaterials: applications in biosensors and nanomedicine
Yang, G., Zhu, C., Du, D., Zhu, J., & Lin, Y. (2015) · Nanoscale · doi:10.1039/c5nr03398e · Cited by 262
Two-dimensional MoS2: A promising building block for biosensors
Gan, X., Zhao, H., & Quan, X. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.03.042 · Cited by 260
Metadata
- Authors
- Wang, T., Zhu, R., Zhuo, J., Zhu, Z., Shao, Y., & Li, M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-11-24
- Volume
- 86
- Issue
- 24
- Pages
- 12064-12069
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2329710948
- Cited by
- 191
- References
- 4
- FWCI
- 7.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.