The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Rapid, Selective, and Ultrasensitive Fluorimetric Analysis of Mercury and Copper Levels in Blood Using Bimetallic Gold–Silver Nanoclusters with “Silver Effect”-Enhanced Red Fluorescence
Abstract
Bimetallic alloying gold-silver nanoclusters (Au-AgNCs) have been synthesized by a one-pot biomineralization synthesis route at a vital molar ratio of Au/Ag precursors in the protein matrix. Unexpectedly, the prepared Au-AgNCs could exhibit dramatically enhanced red fluorescence, which is about 6.5-fold and 4.7-fold higher than that of common AuNCs and core-shell Au@AgNCs, respectively. A rapid, selective, and ultrasensitive fluorimetric method has thereby been developed using Au-AgNCs as fluorescent probes toward the separate detections of Hg(2+) and Cu(2+) ions in blood. The interactions of Au-AgNCs with Hg(2+) and Cu(2+) ions were systematically characterized by microscopy imaging, UV-vis, and fluorescence measurements. It is demonstrated that the "silver effect" gives the Au-AgNCs probes not only greatly enhanced red fluorescence but also the strong capacity to specifically sense Cu(2+) ions in addition to improved response to Hg(2+) ions. Moreover, aided by a Cu(2+) chelating agent, exclusive detection of Hg(2+) ions could also be expected with the coexistence of a high level of Cu(2+) ions, as well as reversible Cu(2+) analysis by restoring the fluorescence of Au-AgNCs. Additionally, Au-AgNCs with strong red fluorescence could facilitate fluorimetric analysis with minimal interference from blood backgrounds. Such an Au-AgNCs-based fluorimetric method can allow for the selective analysis of Hg(2+) and Cu(2+) ions down to 0.30 nM and 0.60 nM in blood, respectively, promising a novel detection method to be applied in the clinical laboratory.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanoalloys: From Theory to Applications of Alloy Clusters and Nanoparticles
Ferrando, R., Jellinek, J., & Johnston, R. L. (2008) · Chemical Reviews · doi:10.1021/cr040090g · Cited by 3,690
Charging Effects on Bonding and Catalyzed Oxidation of CO on Au 8 Clusters on MgO
Yoon, B., Häkkinen, H., Landman, U., Wörz, A. S., Antonietti, J.-M., Abbet, S., Judai, K., & Heiz, U. (2005) · Science · doi:10.1126/science.1104168 · Cited by 1,430
Essentiality of copper in humans
Uauy, R., Olivares, M., & Gonzalez, M. (1998) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/67.5.952s · Cited by 1,052
Wiechelman, K. J., Braun, R. D., & Fitzpatrick, J. D. (1988) · Analytical Biochemistry · doi:10.1016/0003-2697(88)90383-1 · Cited by 766
Cited by
Luminescent films for chemo- and biosensing
Guan, W., Zhou, W., Lu, J., & Lu, C. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00246j · Cited by 287
Metadata
- Authors
- Zhang, N., Si, Y., Sun, Z., Chen, L., Li, R., Qiao, Y., & Wang, H.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-11-10
- Volume
- 86
- Issue
- 23
- Pages
- 11714-11721
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2331059636
- Cited by
- 238
- References
- 4
- FWCI
- 9.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.