The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Fast and Highly Sensitive Fiber-Enhanced Raman Spectroscopic Monitoring of Molecular H2 and CH4 for Point-of-Care Diagnosis of Malabsorption Disorders in Exhaled Human Breath
Abstract
Breath gas analysis is a novel powerful technique for noninvasive, early-stage diagnosis of metabolic disorders or diseases. Molecular hydrogen and methane are biomarkers for colonic fermentation, because of malabsorption of oligosaccharides (e.g., lactose or fructose) and for small intestinal bacterial overgrowth. Recently, the presence of these gases in exhaled breath was also correlated with obesity. Here, we report on the highly selective and sensitive detection of molecular hydrogen and methane within a complex gas mixture (consisting of H2, CH4, N2, O2, and CO2) by means of fiber-enhanced Raman spectroscopy (FERS). An elaborate FERS setup with a microstructured hollow core photonic crystal fiber (HCPCF) provided a highly improved analytical sensitivity. The simultaneous monitoring of H2 with all other gases was achieved by a combination of rotational (H2) and vibrational (other gases) Raman spectroscopy within the limited spectral transmission range of the HCPCF. The HCPCF was combined with an adjustable image-plane aperture pinhole, in order to separate the H2 rotational Raman bands from the silica background signal and improve the sensitivity down to a limit of detection (LOD) of 4.7 ppm (for only 26 fmol H2). The ability to monitor the levels of H2 and CH4 in a positive hydrogen breath test (HBT) was demonstrated. The FERS sensor possesses a high dynamic range (∼5 orders of magnitude) with a fast response time of few seconds and provides great potential for miniaturization. We foresee that this technique will pave the way for fast, noninvasive, and painless point-of-care diagnosis of metabolic diseases in exhaled human breath.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yu, D., Cheeseman, F., & Vanner, S. (2011) · Gut · doi:10.1136/gut.2009.205476 · Cited by 284
Cited by
Markos, C., Travers, J. C., Abdolvand, A., Eggleton, B. J., & Bang, O. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.045003 · Cited by 314
Surface-enhanced Raman spectroscopy for bioanalysis and diagnosis
Tahir, M. A., Dina, N. E., Cheng, H., Valev, V. K., & Zhang, L. (2021) · Nanoscale · doi:10.1039/d1nr00708d · Cited by 257
Metadata
- Authors
- Hanf, S., Bögözi, T., Keiner, R., Frosch, T., & Popp, J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-12-29
- Volume
- 87
- Issue
- 2
- Pages
- 982-988
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2065048138
- Cited by
- 165
- References
- 1
- FWCI
- 6.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fast and Highly Sensitive Fiber-Enhanced Raman Spectroscopic Monitoring of Molecular H2 and CH4 for Point-of-Care Diagnosis of Malabsorption Disorders in Exhaled Human Breath. https://app.cochat.ai/papers/10.1021/ac503450y
- The paper
- Hanf, S., Bögözi, T., Keiner, R., Frosch, T., & Popp, J. (2015). Fast and Highly Sensitive Fiber-Enhanced Raman Spectroscopic Monitoring of Molecular H2 and CH4 for Point-of-Care Diagnosis of Malabsorption Disorders in Exhaled Human Breath. Analytical Chemistry. https://doi.org/10.1021/ac503450y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.