Direct Introduction of Biological Samples into a LTQ-Orbitrap Hybrid Mass Spectrometer as a Tool for Fast Metabolome Analysis
The DOI matches its Crossref record.
Abstract
We report the direct introduction of biological samples into a high-resolution mass spectrometer, the LTQ-Orbitrap, as a fast tool for metabolomic studies. A proof of concept study was performed on yeast cell extracts that were introduced into the mass spectrometer by using flow injection analysis, with an acquisition time of 3 min. Typical mass spectra contained a few thousand m/z signals, 400 of which were found to be analytically relevant (i.e., their intensity was 3-fold higher than that of the background noise and they occurred in at least 60% of the acquisition profiles under identical experimental conditions). The method was validated by studies of the matrix effect, linearity, and intra-assay precision. Accurate mass measurements in the Orbitrap discriminated between isobaric ions and also indicated the elemental composition of the ions of interest with mass errors below 5 ppm, for identification purposes. The proposed structures were then assessed by MSn experiments via the linear ion trap, together with accurate mass determination of the product ions in the Orbitrap analyzer. When applied to the study of cadmium toxicity, the method was as effective as that initially developed by using LC/ESI-MS/MS for a targeted approach. The same metabolic fingerprints were also subjected to multivariate statistical analyses. The results highlighted a reorganization of amino acid metabolism under cadmium conditions in order to increase the biosynthesis of glutathione.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Orbitrap mass spectrometry: Instrumentation, ion motion and applications
Perry, R. H., Cooks, R. G., & Noll, R. J. (2008) · Mass Spectrometry Reviews · doi:10.1002/mas.20186 · Cited by 514
Evolution of Orbitrap Mass Spectrometry Instrumentation
Eliuk, S., & Makarov, A. (2015) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071114-040325 · Cited by 456
Fuhrer, T., Heer, D., Begemann, B., & Zamboni, N. (2011) · Analytical Chemistry · doi:10.1021/ac201267k · Cited by 418
Guo, K., & Li, L. (2009) · Analytical Chemistry · doi:10.1021/ac900166a · Cited by 396
Promises and pitfalls of untargeted metabolomics
Gertsman, I., & Barshop, B. A. (2018) · Journal of Inherited Metabolic Disease · doi:10.1007/s10545-017-0130-7 · Cited by 271
“Though several groups have published methods that utilize direct injection into mass spectrometers for analysis of metabolites (Madalinski et al 2008; Fuhrer et al 2011), the vast number of researchers utilize inline chromatography in their platforms to minimize ionic suppression and increase both…”
Background
Metadata
- Authors
- Madalinski, G., Godat, E., Alves, S., Lesage, D., Genin, E., Levi, P., Labarre, J., Tabet, J.-C., Ezan, E., & Junot, C.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-03-20
- Volume
- 80
- Issue
- 9
- Pages
- 3291-3303
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2024938665
- Cited by
- 105
- References
- 0
- FWCI
- 4.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Direct Introduction of Biological Samples into a LTQ-Orbitrap Hybrid Mass Spectrometer as a Tool for Fast Metabolome Analysis. https://app.cochat.ai/papers/10.1021/ac7024915
- The paper
- Madalinski, G., Godat, E., Alves, S., Lesage, D., Genin, E., Levi, P., Labarre, J., Tabet, J.-C., Ezan, E., & Junot, C. (2008). Direct Introduction of Biological Samples into a LTQ-Orbitrap Hybrid Mass Spectrometer as a Tool for Fast Metabolome Analysis. Analytical Chemistry. https://doi.org/10.1021/ac7024915
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.