CoChat

Measurement of 13C and 15N Isotopic Composition on Nanomolar Quantities of C and N

Polissar, Pratigya J., Fulton, James M., Junium, Christopher K., Turich, Courtney C., Freeman, Katherine H. · 2009 · Analytical Chemistry
Cited by 94

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

We describe a trapping and chromatography system that cryogenically removes CO(2) and N(2) generated from sample combustion in an elemental analyzer (EA) and introduces these gases into a low-flow helium carrier stream for isotopic analysis. The sample size required for measurement by this system (termed nano-EA/IRMS) is almost 3 orders of magnitude less than conventional EA analyses and fills an important niche in the range of analytical isotopic methods. Only 25 nmol of N and 41 nmol of C are needed to achieve 1.0 per thousand precision (2sigma) from a single measurement while larger samples and replicate measurements provide better precision. Analyses of standards demonstrate that nano-EA measurements are both accurate and precise, even on nanomolar quantities of C and N. Conventional and nano-EA measurements on international and laboratory standards are indistinguishable within analytical precision. Likewise, nano-EA values for international standards do not differ statistically from their consensus values. Both observations indicate the nano-EA measurements are comparable to conventional EA analyses and accurately reproduce the VPDB and AIR isotopic scales. Critical to the success of the nano-EA system is the procedure for removing the blank contribution to the measured values. Statistical treatment of uncertainties for this procedure yields an accurate method for calculating internal and external precision.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac801370c

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 94

Metadata

Authors
Polissar, P. J., Fulton, J. M., Junium, C. K., Turich, C. C., & Freeman, K. H.
Venue
Analytical Chemistry
Published
2008-12-10
Volume
81
Issue
2
Pages
755-763
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W1998000154
Cited by
94
References
1
FWCI
2.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of 13C and 15N Isotopic Composition on Nanomolar Quantities of C and N. https://app.cochat.ai/papers/10.1021/ac801370c
The paper
Polissar, P. J., Fulton, J. M., Junium, C. K., Turich, C. C., & Freeman, K. H. (2009). Measurement of 13C and 15N Isotopic Composition on Nanomolar Quantities of C and N. Analytical Chemistry. https://doi.org/10.1021/ac801370c

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.