The DOI matches its Crossref record.
Combined Charged Residue-Field Emission Model of Macromolecular Electrospray Ionization
Open accessAbstract
The mechanism of the multiple charging of macromolecules in electrospray ionization (ESI) continues to inspire debate and controversy. Recently, we proposed that the number of charges on a macromolecule is determined by the emission of small charge carriers from macromolecule-containing nanodroplets and that, after solvent evaporation, the remaining charge is transferred to the macromolecule. In this study, we tested the applicability of this new theory for macromolecular, positive-ion ESI mass spectrometry by measuring the mean charge states and charge distributions of globular proteins under non-denaturing and denaturing conditions. Predictions of protein mean charge states for native state proteins are in excellent agreement with mass spectrometric measurements, giving strong credence to the proposed theory. Theoretical predictions are also in good agreement with mean charge states measured for proteins in basic solutions (pH = 11.5). For some proteins in acidic solutions (pH = 2.1), the measured mean charge states are anomalously higher than the Rayleigh limit of a water droplet with a volume equivalent to that of the protein. We propose that some macromolecules that are highly charged in solution may desorb from charged droplets of the same polarity in a similar manner to that whereby charge carriers emit from nanodroplets, leading to "supercharged" macromolecular ions. Examination of rate expressions for solvent evaporation and charge-carrier emission demonstrates that the newly proposed model for ESI is consistent with previously reported ion-emission kinetics. Overall, we obtained additional experimental evidence for the charge carrier emission model for macromolecular charging, suggesting opportunities for understanding and applying ESI-MS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Unraveling the Mechanism of Electrospray Ionization
Konermann, L., Ahadi, E., Rodriguez, A. D., & Vahidi, S. (2013) · Analytical Chemistry · doi:10.1021/ac302789c · Cited by 735
Definitions of terms relating to mass spectrometry (IUPAC Recommendations 2013)
Murray, K. K., Boyd, R. K., Eberlin, M. N., Langley, G. J., Li, L., & Naito, Y. (2013) · Pure and Applied Chemistry · doi:10.1351/pac-rec-06-04-06 · Cited by 687
Hall, Z., Politis, A., Bush, M. F., Smith, L. J., & Robinson, C. V. (2012) · Journal of the American Chemical Society · doi:10.1021/ja2096859 · Cited by 267
The Role of the Detergent Micelle in Preserving the Structure of Membrane Proteins in the Gas Phase
Reading, E., Liko, I., Allison, T. M., Benesch, J. L. P., Laganowsky, A., & Robinson, C. V. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201411622 · Cited by 137
Metadata
- Authors
- Hogan, C. J., Carroll, J. A., Rohrs, H. W., Biswas, P., & Gross, M. L.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-12-01
- Volume
- 81
- Issue
- 1
- Pages
- 369-377
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2089214055
- Cited by
- 174
- References
- 0
- FWCI
- 2.99
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Combined Charged Residue-Field Emission Model of Macromolecular Electrospray Ionization. https://app.cochat.ai/papers/10.1021/ac8016532
- The paper
- Hogan, C. J., Carroll, J. A., Rohrs, H. W., Biswas, P., & Gross, M. L. (2009). Combined Charged Residue-Field Emission Model of Macromolecular Electrospray Ionization. Analytical Chemistry. https://doi.org/10.1021/ac8016532
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.