The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Design of Fluorescent Assays for Cyanide and Hydrogen Peroxide Based on the Inner Filter Effect of Metal Nanoparticles
Abstract
We have demonstrated the design of a new type fluorescent assay based on the inner filter effect (IFE) of metal nanoparticles (NPs), which is conceptually different from the previously reported metal NPs-based fluorescent assays. With a high extinction coefficient and tunable plasmon absorption feature, metal NPs are expected to be capable of functioning as a powerful absorber to tune the emission of the fluorophore in the IFE-based fluorescent assays. In this work, we presented two proof-of-concept examples based on the IFE of Au NPs by choosing MDMO-PPV as a model fluorophore, whose fluorescence could be tuned by the absorbance of Au NPs with a much higher sensitivity than the corresponding absorbance approach. While the first assay worked in a turn-on mode upon the etching of Au NPs by the analyte, CN(-), the second one functioned in a turn-off mode upon the catalytic growth of Au NPs by the analyte, H(2)O(2). As a result, the present IFE-based approach can detect cyanide ranging from 1.0 x 10(-6) to 6.0 x 10(-4) M with a detection limit of 6.0 x 10(-7) M and H(2)O(2) ranging from 1.5 x 10(-7) to 2.2 x 10(-5) M with a detection limit of 8.5 x 10(-8) M, respectively. Notably, the present IFE-based approach allows the design of fluorescent assays in a more simple, time-saving, and economical approach when compared with conventional metal NPs-based fluorescent assays, since no modification step of the fluorophore was needed any more.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fluorescence-based glucose sensors
Pickup, J. C., Hussain, F., Evans, N. D., Rolinski, O. J., & Birch, D. J. S. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.10.002 · Cited by 616
Cited by
Ultra-small fluorescent metal nanoclusters: Synthesis and biological applications
Shang, L., Dong, S., & Nienhaus, G. U. (2011) · Nano Today · doi:10.1016/j.nantod.2011.06.004 · Cited by 1,502
Self-citationWu, X., Song, Y., Yan, X., Zhu, C., Ma, Y., Du, D., & Lin, Y. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.03.010 · Cited by 328
Zhang, C., Zhang, S., Yan, Y., Xia, F., Huang, A., & Xian, Y. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b16423 · Cited by 304
Metadata
- Authors
- Shang, L., & Dong, S.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-01-13
- Volume
- 81
- Issue
- 4
- Pages
- 1465-1470
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2002534810
- Cited by
- 241
- References
- 1
- FWCI
- 5.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.