The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Development of a Heat-Induced Surface-Enhanced Raman Scattering Sensing Method for Rapid Detection of Glutathione in Aqueous Solutions
Abstract
In this paper, a direct and simple detection method based on surface-enhanced Raman scattering (SERS) named "heat-induced SERS sensing method" is proposed for rapid determination of glutathione in aqueous solutions. It was found that highly enhanced SERS spectra of glutathione can be obtained if the silver colloids adsorbed with the analyte were heated up before the SERS measurement. Besides, it was revealed that silver particles with a size of approximately 60 nm are suitable for this study and that the SERS intensity is also influenced by the dropped sample volume, drying temperature, buffer concentration, and pH of the solution. It is noted that the thiol group of glutathione has a particularly strong interaction with a silver surface compared with other small biological molecules without a thiol group, validating this method to detect glutathione selectively. Under the optimal conditions, the detection of glutathione can be finished within 5 min, and the detection limit of ca. 50 nM can be reached, which is much better than the reported detection limit of glutathione (approximately 1 microM) by SERS. The enhancement factor of the proposed heat-induced SERS sensing method for the detection of glutathione is about 7.5 x 10(6). The proposed method holds a specific selectivity toward glutathione, facilitating its rapid detection in practical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface raman spectroelectrochemistry
Jeanmaire, D. L., & Van Duyne, R. P. (1977) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/s0022-0728(77)80224-6 · Cited by 4,738
Surface-Enhanced Raman Spectroscopy
Haynes, C. L., McFarland, A. D., & Van Duyne, R. P. (2005) · Analytical Chemistry · doi:10.1021/ac053456d · Cited by 1,144
Cheesman, B. V., Arnold, A. P., & Rabenstein, D. L. (1988) · Journal of the American Chemical Society · doi:10.1021/ja00227a014 · Cited by 149
Cited by
Surface-enhanced Raman spectroscopy: a half-century historical perspective
Yi, J., You, E.-M., Hu, R., Wu, D.-Y., Liu, G.-K., Yang, Z.-L., Zhang, H., Gu, Y., Wang, Y.-H., Wang, X., et al. (2025) · Chemical Society Reviews · doi:10.1039/d4cs00883a · Cited by 382
Self-citation
Metadata
- Authors
- Huang, G. G., Han, X. X., Hossain, M. K., & Ozaki, Y.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-06-11
- Volume
- 81
- Issue
- 14
- Pages
- 5881-5888
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2042920914
- Cited by
- 163
- References
- 3
- FWCI
- 3.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of a Heat-Induced Surface-Enhanced Raman Scattering Sensing Method for Rapid Detection of Glutathione in Aqueous Solutions. https://app.cochat.ai/papers/10.1021/ac900392s
- The paper
- Huang, G. G., Han, X. X., Hossain, M. K., & Ozaki, Y. (2009). Development of a Heat-Induced Surface-Enhanced Raman Scattering Sensing Method for Rapid Detection of Glutathione in Aqueous Solutions. Analytical Chemistry. https://doi.org/10.1021/ac900392s
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.