The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Multifunctional and Highly Sensitive Precolumn Reagents for Amino Acids in Liquid Chromatography/Tandem Mass Spectrometry
Abstract
We have developed novel precolumn derivatization reagent, p-N,N,N-trimethylammonioanilyl N'-hydroxysuccinimidyl carbamate iodide (TAHS), for sensitive analyses of amino acids using high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS). TAHS, an activated carbamate, was reacted briefly with the amino group to form a ureide bond under mild condition. The derivatives provided selective cleavage at the binding site between the reagent and the amino acid in the collision cell of the mass spectrometer and produced a characteristic fragment derived from the reagent moiety. Using the precursor ion scan mode of the tandem mass spectrometry, amino acids derivatized with the reagents were simultaneously measured on the chromatogram. Selective cleavage also enabled the straightforward isotope ratio analysis of amino acids by the selected reaction monitoring mode, which was applicable in (13)C metabolic flux analysis. TAHS, which contains a cationic quaternary amine, achieved subfemtomole to attomole levels of amino acids detection by measurement in the selected reaction monitoring mode. We also synthesized trideuteriummethyl-substituted TAHS, TAHS-d(3), and demonstrated that the combination of TAHS and TAHS-d(3) is useful in comparing amino acid concentrations between two different samples using a single LC/MS/MS measurement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative analysis of complex protein mixtures using isotope-coded affinity tags
Gygi, S. P., Rist, B., Gerber, S. A., Turecek, F., Gelb, M. H., & Aebersold, R. (1999) · Nature Biotechnology · doi:10.1038/13690 · Cited by 4,683
Ross, P. L., Huang, Y. N., Marchese, J. N., Williamson, B., Parker, K., Hattan, S., Khainovski, N., Pillai, S., Dey, S., Daniels, S., et al. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400129-mcp200 · Cited by 4,401
Cited by
Deuterium‐ and Tritium‐Labelled Compounds: Applications in the Life Sciences
Atzrodt, J., Derdau, V., Kerr, W. J., & Reid, M. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201704146 · Cited by 810
Miyagi, Y., Higashiyama, M., Gochi, A., Akaike, M., Ishikawa, T., Miura, T., Saruki, N., Bando, E., Kimura, H., Imamura, F., et al. (2011) · PLoS ONE · doi:10.1371/journal.pone.0024143 · Cited by 435
Self-citationChemical labeling strategies for small molecule natural product detection and isolation
Hughes, C. C. (2021) · Natural Product Reports · doi:10.1039/d0np00034e · Cited by 31
Metadata
- Authors
- Shimbo, K., Yahashi, A., Hirayama, K., Nakazawa, M., & Miyano, H.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-05-29
- Volume
- 81
- Issue
- 13
- Pages
- 5172-5179
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1993229728
- Cited by
- 176
- References
- 2
- FWCI
- 4.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.