The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
In Situ Metabolic Profiling of Single Cells by Laser Ablation Electrospray Ionization Mass Spectrometry
Abstract
Depending on age, phase in the cell cycle, nutrition, and environmental factors, individual cells exhibit large metabolic diversity. To explore metabolic variations in cell populations, laser ablation electrospray ionization (LAESI) mass spectrometry (MS) was used for the in situ analysis of individual cells at atmospheric pressure. Single cell ablation was achieved by delivering mid-IR laser pulses through the etched tip of a GeO(2)-based glass fiber. Metabolic analysis was performed from single cells and small cell populations of Allium cepa and Narcissus pseudonarcissus bulb epidermis, as well as single eggs of Lytechinus pictus. Of the 332 peaks detected for A. cepa, 35 were assigned to metabolites with the help of accurate ion masses and tandem MS. The metabolic profiles from single cells of the two plant species included a large variety of oligosaccharides including possibly fructans in A. cepa, and alkaloids, e.g., lycorine in N. pseudonarcissus. Analysis of adjacent individual cells with a difference in pigmentation showed that, in addition to essential metabolites found in both variants, the pigmented cells contained anthocyanidins, other flavonoids, and their glucosides. Analysis of single epidermal cells from different scale leaves in an A. cepa bulb showed metabolic differences corresponding to their age. Our results indicate the feasibility of using LAESI-MS for the in situ analysis of metabolites in single cells with potential applications in studying cell differentiation, changes due to disease states, and response to xenobiotics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tsien, R. Y. (1998) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.67.1.509 · Cited by 6,143
Mass Spectrometry Sampling Under Ambient Conditions with Desorption Electrospray Ionization
Takáts, Z., Wiseman, J. M., Gologan, B., & Cooks, R. G. (2004) · Science · doi:10.1126/science.1104404 · Cited by 3,324
Emmert-Buck, M. R., Bonner, R. F., Smith, P. D., Chuaqui, R. F., Zhuang, Z., Goldstein, S. R., Weiss, R. A., & Liotta, L. A. (1996) · Science · doi:10.1126/science.274.5289.998 · Cited by 2,534
Nemes, P., & Vertes, A. (2007) · Analytical Chemistry · doi:10.1021/ac071181r · Cited by 817
Self-citationOnions: A Source of Unique Dietary Flavonoids
Slimestad, R., Fossen, T., & Vågen, I. M. (2007) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf0712503 · Cited by 624
Mass Spectrometric Imaging of Highly Curved Membranes During Tetrahymena Mating
Ostrowski, S. G., Van Bell, C. T., Winograd, N., & Ewing, A. G. (2004) · Science · doi:10.1126/science.1099791 · Cited by 330
Nuclear magnetic resonance imaging of a single cell
Aguayo, J. B., Blackband, S. J., Schoeniger, J. S., Mattingly, M. A., & Hintermann, M. (1986) · Nature · doi:10.1038/322190a0 · Cited by 327
Wilson, R. H., Smith, A. C., Kačuráková, M., Saunders, P. K., Wellner, N., & Waldron, K. W. (2000) · Plant Physiology · doi:10.1104/pp.124.1.397 · Cited by 296
Nemes, P., Barton, A. A., Li, Y., & Vertes, A. (2008) · Analytical Chemistry · doi:10.1021/ac8004082 · Cited by 244
Self-citationTalaty, N., Takáts, Z., & Cooks, R. G. (2005) · The Analyst · doi:10.1039/b511161g · Cited by 209
Real-time visualization of intracellular hydrodynamics in single living cells
Potma, E. O. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.031575698 · Cited by 194
Atmospheric Pressure Molecular Imaging by Infrared MALDI Mass Spectrometry
Li, Y., Shrestha, B., & Vertes, A. (2007) · Analytical Chemistry · doi:10.1021/ac061577n · Cited by 193
Self-citationTHE DISTRIBUTION OF FRUCTANS IN ONIONS
Darbyshire, B., & Henry, R. J. (1978) · New Phytologist · doi:10.1111/j.1469-8137.1978.tb01600.x · Cited by 147
Mass Spectrometric Method for Analyzing Metabolites in Yeast with Single Cell Sensitivity
Amantonico, A., Oh, J. Y., Sobek, J., Heinemann, M., & Zenobi, R. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200705923 · Cited by 143
Measuring the peptides in individual organelles with mass spectrometry
Rubakhin, S. S., Garden, R. W., Fuller, R. R., & Sweedler, J. V. (2000) · Nature Biotechnology · doi:10.1038/72622 · Cited by 137
Hofstadler, S. A., Severs, J. C., Smith, R., Swanek, F. D., & Ewing, A. G. (1996) · Rapid Communications in Mass Spectrometry · Cited by 131
Sampson, J. S., Murray, K. K., & Muddiman, D. C. (2008) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2008.12.003 · Cited by 110
Stahl, B., Linos, A., Karas, M., Hillenkamp, F., & Steup, M. (1997) · Analytical Biochemistry · doi:10.1006/abio.1997.2011 · Cited by 100
Kehr, J. (2003) · Current Opinion in Plant Biology · doi:10.1016/j.pbi.2003.09.002 · Cited by 97
Malik, Z., Dishi, M., & Garini, Y. (1996) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1996.tb05663.x · Cited by 80
Live Single-Cell Molecular Analysis by Video-Mass Spectrometry
Tsuyama, N., Mizuno, H., Tokunaga, E., & Masujima, T. (2008) · Analytical Sciences · doi:10.2116/analsci.24.559 · Cited by 72
Chemical Microscopy Applied to Biological Systems
Navratil, M., Mabbott, G. A., & Arriaga, E. A. (2006) · Analytical Chemistry · doi:10.1021/ac0606756 · Cited by 55
Early plume expansion in atmospheric pressure midinfrared laser ablation of water-rich targets
Chen, Z., & Vértes, Á. (2008) · Physical Review E · doi:10.1103/physreve.77.036316 · Cited by 43
Prabhakar, S., Nazarian, J., Hathout, Y., Hoffman, E. P., & Vértes, Á. (2008) · Metabolomics · doi:10.1007/s11306-008-0147-x · Cited by 43
Cited by
Single cell analysis: the new frontier in ‘omics’
Wang, D., & Bodovitz, S. (2010) · Trends in Biotechnology · doi:10.1016/j.tibtech.2010.03.002 · Cited by 673
Single-Cell Metabolomics: Analytical and Biological Perspectives
Zenobi, R. (2013) · Science · doi:10.1126/science.1243259 · Cited by 661
Ambient Sampling/Ionization Mass Spectrometry: Applications and Current Trends
Harris, G. A., Galhena, A. S., & Fernández, F. M. (2011) · Analytical Chemistry · doi:10.1021/ac200918u · Cited by 527
Mass spectrometry imaging under ambient conditions
Wu, C., Dill, A. L., Eberlin, L. S., Cooks, R. G., & Ifa, D. R. (2013) · Mass Spectrometry Reviews · doi:10.1002/mas.21360 · Cited by 488
Mass Spectrometry: Recent Advances in Direct Open Air Surface Sampling/Ionization
Monge, M. E., Harris, G. A., Dwivedi, P., & Fernández, F. M. (2013) · Chemical Reviews · doi:10.1021/cr300309q · Cited by 476
Metadata
- Authors
- Shrestha, B., & Vertes, A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-09-17
- Volume
- 81
- Issue
- 20
- Pages
- 8265-8271
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2105976216
- Cited by
- 273
- References
- 24
- FWCI
- 9.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.