The DOI matches its Crossref record.
Petroleum Crude Oil Characterization by IMS-MS and FTICR MS
Abstract
Here, complementary ion mobility/mass spectrometry (IM/MS) and ultrahigh-resolution Fourier transform ion cyclotron resonance (FTICR) MS analyses of light, medium, and heavy petroleum crude oils yielded distributions of the heteroatom-containing hydrocarbons, as well as multiple conformational classes. The IM/MS technique provides unique fingerprints for fast identification of signature conformational/compositional patterns, whereas FTICR MS analysis provides comprehensive heteroatom class distributions. IM/MS and FTICR MS results reveal an increase in compositional complexity in proceeding from light to medium to heavy crude oils. Inspection of the mobility results shows a high structural diversity for the C(n)H(h)XY (XY = N(1), S(1), N(1), O(1), NS, SO(1-2), NO(1-2), etc.) series, as well as a shift from planar to more compact three-dimensional structures with increasing mass.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gas-phase separation using a trapped ion mobility spectrometer
Fernandez-Lima, F., Kaplan, D. A., Suetering, J., & Park, M. A. (2011) · International Journal for Ion Mobility Spectrometry · doi:10.1007/s12127-011-0067-8 · Cited by 315
Self-citationHigh Resolution Mass Spectrometry
Xian, F., Hendrickson, C. L., & Marshall, A. G. (2012) · Analytical Chemistry · doi:10.1021/ac203191t · Cited by 281
Self-citationIon dynamics in a trapped ion mobility spectrometer
Hernandez, D. R., DeBord, J. D., Ridgeway, M. E., Kaplan, D. A., Park, M. A., & Fernandez-Lima, F. (2014) · The Analyst · doi:10.1039/c3an02174b · Cited by 267
Self-citation
Metadata
- Authors
- Fernandez-Lima, F. A., Becker, C., McKenna, A. M., Rodgers, R. P., Marshall, A. G., & Russell, D. H.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-11-11
- Volume
- 81
- Issue
- 24
- Pages
- 9941-9947
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2060484862
- Cited by
- 188
- References
- 0
- FWCI
- 4.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.