The DOI matches its Crossref record.
Integrated Ultramicroelectrode−Nanopipet Probe for Concurrent Scanning Electrochemical Microscopy and Scanning Ion Conductance Microscopy
Abstract
Scanning ion conductance microscopy (SICM) has developed into a powerful tool for imaging a range of biophysical systems. In addition, SICM has been integrated with a range of other techniques, allowing for the simultaneous collection of complementary information including near-field optical and electrophysiological properties. However, SICM imaging remains insensitive to electrochemical properties, which play an important role in both biological and nonbiological systems. In this work, we demonstrate the fabrication and application of a nanopipet probe with an integrated ultramicroelectrode (UME) for concurrent SICM and scanning electrochemical microscopy (SECM). The fabrication process utilizes atomic layer deposition (ALD) of aluminum oxide to conformally insulate a gold-coated nanopipet and focused ion beam (FIB) milling to precisely expose a UME at the pipet tip. Fabricated probes are characterized by both scanning electron microscopy and cyclic voltammetry and exhibit a 100 nm diameter nanopipet tip and a UME with an effective radius of 294 nm. The probes exhibit positive and negative feedback responses on approach to conducting and insulating surfaces, respectively. The suitability of the probes for SECM-SICM imaging is demonstrated by both feedback-mode and substrate generation/tip collection-mode imaging on patterned surfaces. This probe geometry enables successful SECM-SICM imaging on features as small as 180 nm in size.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Crystallinity of inorganic films grown by atomic layer deposition: Overview and general trends
Miikkulainen, V., Leskelä, M., Ritala, M., & Puurunen, R. L. (2013) · Journal of Applied Physics · doi:10.1063/1.4757907 · Cited by 1,413
Shi, W., Friedman, A. K., & Baker, L. A. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04260 · Cited by 430
Ebejer, N., Güell, A. G., Lai, S. C. S., McKelvey, K., Snowden, M. E., & Unwin, P. R. (2013) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-062012-092650 · Cited by 355
Takahashi, Y., Shevchuk, A. I., Novak, P., Murakami, Y., Shiku, H., Korchev, Y. E., & Matsue, T. (2010) · Journal of the American Chemical Society · doi:10.1021/ja1029478 · Cited by 297
Takahashi, Y., Shevchuk, A. I., Novak, P., Zhang, Y., Ebejer, N., Macpherson, J. V., Unwin, P. R., Pollard, A. J., Roy, D., Clifford, C. A., et al. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201102796 · Cited by 284
Belov, M. E., Damoc, E., Denisov, E., Compton, P. D., Horning, S., Makarov, A. A., & Kelleher, N. L. (2013) · Analytical Chemistry · doi:10.1021/ac4029328 · Cited by 175
Kuzuya, A., Nomura, S.-I. M., Toyota, T., Nakakuki, T., & Murata, S. (2023) · IEEE Transactions on Molecular, Biological and Multi-Scale Communications · doi:10.1109/tmbmc.2023.3304243 · Cited by 29
Metadata
- Authors
- Comstock, D. J., Elam, J. W., Pellin, M. J., & Hersam, M. C.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-01-14
- Volume
- 82
- Issue
- 4
- Pages
- 1270-1276
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1989001895
- Cited by
- 169
- References
- 0
- FWCI
- 10.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.