Part-per-Trillion Determination of Pharmaceuticals, Pesticides, and Related Organic Contaminants in River Water by Solid-Phase Extraction Followed by Comprehensive Two-Dimensional Gas Chromatography Time-of-Flight Mass Spectrometry
The DOI matches its Crossref record.
Abstract
An analytical procedure based on comprehensive two-dimensional gas chromatography (GC x GC) coupled with time-of-flight mass spectrometry (TOF-MS) for the simultaneous determination of 97 organic contaminants at trace concentration in river water is presented. The target analytes included 13 pharmaceuticals, 18 plasticizers, 8 personal care products, 9 acid herbicides, 8 triazines, 10 organophosphorous compounds, 5 phenylureas, 12 organochlorine biocides, 9 polycyclic aromatic hydrocarbons (PAHs), and 5 benzothiazoles and benzotriazoles. The best resolution of the target analytes in the contour plots was obtained when a nonpolar stationary phase was used in the first dimension and polar one in the second. However, in the opposite configuration, polar-nonpolar, the retention time in the second dimension exhibited a strong correlation with the log Kow (p < 0.01), and it was proposed as an additional identification criteria. The developed methodology is based on a polymeric solid-phase extraction followed by in GC-port methylation and GC x GC/TOF-MS determination. Moreover, limits of detection (LODs) and quantification (LOQs) ranged from 0.5 to 100 ng/L and from 2 to 185 ng/L, respectively. Repeatability was always lower than 20%. Finally, the developed method has been successfully applied to the determination of incurred target analytes in four river waters subjected to a different anthropogenic pressure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Matamoros, V., Gutiérrez, R., Ferrer, I., García, J., & Bayona, J. M. (2015) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2015.02.002 · Cited by 466
Self-citationMatamoros, V., Uggetti, E., García, J., & Bayona, J. M. (2016) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2015.08.050 · Cited by 329
Self-citationGrasel, F. D. S., Ferrão, M. F., & Wolf, C. R. (2016) · Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2015.08.020 · Cited by 269
Houtman, C. J. (2010) · Journal of Integrative Environmental Sciences · doi:10.1080/1943815x.2010.511648 · Cited by 264
Use of Full-Scale Hybrid Horizontal Tubular Photobioreactors to Process Agricultural Runoff
García-Galán, M. J., Gutiérrez, R., Uggetti, E., Matamoros, V., García, J., & Ferrer, I. (2018) · Biosystems Engineering · doi:10.1016/j.biosystemseng.2017.11.016 · Cited by 72
Casado, J., Nescatelli, R., Rodríguez, I., Ramil, M., Marini, F., & Cela, R. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.01.068 · Cited by 37
Metadata
- Authors
- Matamoros, V., Jover, E., & Bayona, J. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-12-28
- Volume
- 82
- Issue
- 2
- Pages
- 699-706
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1965172160
- Cited by
- 122
- References
- 0
- FWCI
- 21.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.