The DOI matches its Crossref record.
Temperature-Responsive Chromatography Using Poly(N-isopropylacrylamide)-Modified Silica
Abstract
A new concept in chromatography is proposed that utilizes a temperature-responsive surface with a constant aqueous mobile phase. The surface of the silica stationary phase in high-performance liquid chromatography (HPLC) has been modified with temperature-responsive polymers to exhibit temperature-controlled hydrophilic/hydrophobic changes. Poly(N-isopropylacrylamide) (PIPAAm) was grafted onto (aminopropyl)silica using an activated ester-amine coupling method. These grafted silica surfaces show hydrophilic properties at lower temperatures which, as temperature increases, transform to hydrophobic surface properties. The elution profile of five mixed steroids on an HPLC column packed with this material depends largely on the temperature of the aqueous mobile phase. Retention times increase with increasing temperature without any change in the eluent. Changes in the retention times of hydrophobic steroids were larger than those for hydrophilic steroids. The temperature-responsive interaction between PIPAAm-modified silica and these steroids is proposed to result from changes in the surface properties of the HPLC stationary phase by the transition of hydrophilic/hydrophobic surface-grafted IPAAm polymers. We demonstrate a novel and useful new chromatography system in which surface properties and the resulting function of the HPLC stationary phase are controlled by external temperature changes. This method should be effective in biological and biomedical separations of peptides and proteins using only aqueous mobile phases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chung, J. E., Yokoyama, M., Yamato, M., Aoyagi, T., Sakurai, Y., & Okano, T. (1999) · Journal of Controlled Release · doi:10.1016/s0168-3659(99)00029-2 · Cited by 599
Self-citationSeparation efficiencies in hydrophilic interaction chromatography
Ikegami, T., Tomomatsu, K., Takubo, H., Horie, K., & Tanaka, N. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.01.075 · Cited by 419
Inner core segment design for drug delivery control of thermo-responsive polymeric micelles
Chung, J. E., Yokoyama, M., & Okano, T. (2000) · Journal of Controlled Release · doi:10.1016/s0168-3659(99)00242-4 · Cited by 364
Self-citationSeuring, J., & Agarwal, S. (2012) · Macromolecules · doi:10.1021/ma300355k · Cited by 301
Alexander, A., Ajazuddin, Khan, J., Saraf, S., & Saraf, S. (2014) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2014.07.005 · Cited by 249
Metadata
- Authors
- Kanazawa, H., Yamamoto, K., Matsushima, Y., Takai, N., Kikuchi, A., Sakurai, Y., & Okano, T.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-01-01
- Volume
- 68
- Issue
- 1
- Pages
- 100-105
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2090902790
- Cited by
- 432
- References
- 0
- FWCI
- 6.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Temperature-Responsive Chromatography Using Poly(N-isopropylacrylamide)-Modified Silica. https://app.cochat.ai/papers/10.1021/ac950359j
- The paper
- Kanazawa, H., Yamamoto, K., Matsushima, Y., Takai, N., Kikuchi, A., Sakurai, Y., & Okano, T. (1996). Temperature-Responsive Chromatography Using Poly(N-isopropylacrylamide)-Modified Silica. Analytical Chemistry. https://doi.org/10.1021/ac950359j
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.