The DOI matches its Crossref record.
Application of Molecular Imprinting to the Development of Aqueous Buffer and Organic Solvent Based Radioligand Binding Assays for ( S )-Propranolol
Abstract
Antibody mimics have been prepared by molecular imprinting of (S)-propranolol and applied in the development of radioligand binding assays for the imprint species. In the assays, polymer particles, radioligand, and analyte were incubated either in an organic solvent or an aqueous buffer, with similarly high sensitivity under both set of conditions. Optimization of the assay conditions led to 100-1000-fold improvements in the limit of determination and 100-1000-fold reductions of the amount of imprinted polymer used, compared with previous studies of this novel type of assay. The present assay uses only 10-50 μg of polymer, and the limit of determination is about 6 nM. The toluene-based assay showed excellent enantioselectivity, the cross-reactivity of the R enantiomer being only 1%, which is better than that demonstrated by biological antibodies. The aqueous buffer based assay showed high substrate selectivity for propranolol in the presence of structurally similar β-blockers. The different selectivity profiles obtained are due to a different balance between hydrophobic and polar interactions in toluene and water, since polar interactions, such as hydrogen bonds, are strong in apolar solvents and hydrophobic interactions are strong in water.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Alexander, C., Andersson, H. S., Andersson, L. I., Ansell, R. J., Kirsch, N., Nicholls, I. A., O'Mahony, J., & Whitcombe, M. J. (2006) · Journal of Molecular Recognition · doi:10.1002/jmr.760 · Cited by 1,248
Self-citationStimulus-responsive hydrogels: theory, modern advances, and applications
Koetting, M. C., Peters, J. T., Steichen, S. D., & Peppas, N. A. (2015) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2015.04.001 · Cited by 1,191
Solid-phase extraction: method development, sorbents, and coupling with liquid chromatography
Hennion, M.-C. (1999) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)00832-8 · Cited by 1,044
Solid-phase extraction of organic compounds: A critical review. part ii
Andrade-Eiroa, A., Canle, M., Leroy-Cancellieri, V., & Cerdà, V. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.08.014 · Cited by 437
Yoshimatsu, K., Reimhult, K., Krozer, A., Mosbach, K., Sode, K., & Ye, L. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.11.004 · Cited by 427
Metadata
- Authors
- Andersson, L. I.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-01-01
- Volume
- 68
- Issue
- 1
- Pages
- 111-117
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2010407672
- Cited by
- 316
- References
- 0
- FWCI
- 24.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Application of Molecular Imprinting to the Development of Aqueous Buffer and Organic Solvent Based Radioligand Binding Assays for ( S )-Propranolol. https://app.cochat.ai/papers/10.1021/ac950668+
- The paper
- Andersson, L. I. (1996). Application of Molecular Imprinting to the Development of Aqueous Buffer and Organic Solvent Based Radioligand Binding Assays for ( S )-Propranolol. Analytical Chemistry. https://doi.org/10.1021/ac950668%2B
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.