Sample Preparation Using a Miniaturized Supported Liquid Membrane Device Connected On-Line to Packed Capillary Liquid Chromatography
The DOI matches its Crossref record.
Abstract
A miniaturized supported liquid membrane device has been developed for sample preparation and connected on-line to a packed capillary liquid chromatograph. The device consists of hydrophobic polypropylene hollow fiber, inserted and fastened in a cylindrical channel in a Kel-F piece. The pores of the fiber are filled with an organic solvent, in this study 6-undecanone, thus forming a liquid membrane. The sample is pumped on the outside of the hollow fiber (donor), and the analytes are selectively enriched and trapped in the fiber lumen (acceptor). With this approach, the volume of the acceptor solution can be kept as low as 1-2 μL. This stagnant acceptor solution is then transferred through capillaries attached to the fiber ends to the LC system. The system was tested with a secondary amine (bambuterol), as a model substance in aqueous standard solutions as well as in plasma. The best extraction efficiency in aqueous solution, with an acceptor volume of 1.9 μL, was 32.5% at a donor flow rate of 2.5 μL/min. At flow rates above 20 μL/min, the concentration enrichment per time unit was approximately constant, at 0.9 times/min, i.e., 9 times enrichment in about 10 min. The overall repeatability (RSD) for spiked plasma samples was ∼4% (n = 12). Linear calibration curves of peak area versus bambuterol concentration were obtained for both aqueous standard solutions and spiked plasma samples. The detection limit for bambuterol in plasma, after 10 min of extraction at a flow rate of 24 μL/min, was 80 nM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pedersen-Bjergaard, S., & Rasmussen, K. E. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.08.088 · Cited by 486
Membrane-based techniques for sample enrichment
Jönsson, J. Å., & Mathiasson, L. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00922-5 · Cited by 288
Self-citationMa, M., & Cantwell, F. F. (1999) · Analytical Chemistry · doi:10.1021/ac9805899 · Cited by 222
Non-conventional solvents in liquid phase microextraction and aqueous biphasic systems
An, J., Trujillo-Rodríguez, M. J., Pino, V., & Anderson, J. L. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.04.012 · Cited by 128
Díaz-Álvarez, M., & Martín-Esteban, A. (2022) · Advances in Sample Preparation · doi:10.1016/j.sampre.2022.100047 · Cited by 43
“In LPME, a water-immiscible organic solvent is immobilized as a thin supported liquid membrane (SLM) in the pores of a porous membrane [7] .”
Metadata
- Authors
- Thordarson, E., Pálmarsdóttir, S., Mathiasson, L., & Jönsson, J. Å.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-08-01
- Volume
- 68
- Issue
- 15
- Pages
- 2559-2563
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2013367689
- Cited by
- 77
- References
- 0
- FWCI
- 4.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sample Preparation Using a Miniaturized Supported Liquid Membrane Device Connected On-Line to Packed Capillary Liquid Chromatography. https://app.cochat.ai/papers/10.1021/ac950929f
- The paper
- Thordarson, E., Pálmarsdóttir, S., Mathiasson, L., & Jönsson, J. Å. (1996). Sample Preparation Using a Miniaturized Supported Liquid Membrane Device Connected On-Line to Packed Capillary Liquid Chromatography. Analytical Chemistry. https://doi.org/10.1021/ac950929f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.