Quantification of Polycyclic Aromatic Hydrocarbons and Polychlorinated Dibenzo- p -dioxins in Human Serum by Combined Micelle-Mediated Extraction (Cloud-Point Extraction) and HPLC
The DOI matches its Crossref record.
Abstract
Quantification of polycyclic aromatic hydrocarbons (PAHs) and polychlorinated dibenzo-p-dioxins (PCDDs) usually requires preconcentration and cleanup prior to analysis. These procedures often involve using large amounts of toxic organic solvents. The sample preparation from serum is even more complex because of the coextraction of lipids and other nonpolar serum components. We describe the unprecedented use of cloud-point extraction to preconcentrate, extract, and clean up PAHs and PCDDs from human serum using the nonionic surfactant Triton X-100. The samples were analyzed by high-performance liquid chromatography with ultraviolet detection. The phase separation was induced by the addition of salt to the micellar serum solutions. The surfactant-rich phase was treated with acetonitrile and water to precipitate and remove some of the unwanted substances in the serum sample extract without significantly affecting the recoveries of the analytes. The favorable characteristics of cloud-point extraction discussed here strengthen its potential use as an alternative to other techniques of separation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Micelle-mediated separation and cloud-point extraction
Paleologos, E. K., Giokas, D. L., & Karayannis, M. I. (2005) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2005.01.013 · Cited by 483
Quina, F. H., & Hinze, W. L. (1999) · Industrial & Engineering Chemistry Research · doi:10.1021/ie980389n · Cited by 424
Carabias-Martı́nez, R., Rodrı́guez-Gonzalo, E., Moreno-Cordero, B., Pérez-Pavón, J. L., Garcı́a-Pinto, C., & Fernández Laespada, E. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00837-2 · Cited by 392
Chen, J., & Teo, K. C. (2001) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)01367-8 · Cited by 355
Chen, J., & Teo, K. C. (2001) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)00849-2 · Cited by 194
Recent developments and applications of cloud point extraction: A critical review
Mortada, W. I. (2020) · Microchemical Journal · doi:10.1016/j.microc.2020.105055 · Cited by 187
Sosa Ferrera, Z., Padrón Sanz, C., Mahugo Santana, C., & Santana Rodrı́guez, J. J. (2004) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(04)00732-0 · Cited by 184
Tani, H., Kamidate, T., & Watanabe, H. (1997) · Journal of Chromatography A · doi:10.1016/s0021-9673(97)00345-2 · Cited by 176
Madej, K. (2009) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.02.002 · Cited by 160
Rubio, S. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-020-02559-y · Cited by 113
Metadata
- Authors
- Sirimanne, S. R., Barr, J. R., Patterson, D. G., & Ma, L.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-05-01
- Volume
- 68
- Issue
- 9
- Pages
- 1556-1560
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1985640078
- Cited by
- 111
- References
- 0
- FWCI
- 4.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.