The DOI matches its Crossref record.
Silica Xerogel as a Continuous Column Support for High-Performance Liquid Chromatography
Abstract
A preliminary study of the chromatographic performance and permeability of a continuous silica xerogel column under reversed-phase HPLC conditions was performed. A porous chromatographic support was synthesized inside a 0.32 mm i.d. × 13 cm fused silica tube from potassium silicate solution and derivatized with dimethyloctadecylchlorosilane. The plate height at 0.01 cm/s (0.5 μL/min), near the apparent optimum linear velocity, was about 65 μm. The column efficiencies in terms of numbers of plates per meter were 5000 and 13 000 for ethyl benzoate (k = 0.8) and naphthalene (k = 2.0), respectively, at 0.5 μL/min. The major parameter affecting column efficiency was the heterogeneous morphology of the xerogel, modifications to which are expected to improve chromatographic performance. The column provided efficiencies comparable to those reported for continuous polymeric columns but less than that previously reported for a continuous silica column. Gradient elution mode was demonstrated with a mixture of polycyclic aromatic hydrocarbons. The column was highly permeable, exhibiting a linear dependence of pressure to flow rate and a back pressure of only 632 psi at 10 μL/min when a 95% aqueous mobile phase was used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Monolithic columns in high-performance liquid chromatography
Guiochon, G. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.090 · Cited by 831
Porous polymer monoliths: Amazingly wide variety of techniques enabling their preparation
Svec, F. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.09.073 · Cited by 577
Monolithic silica columns for high-efficiency chromatographic separations
Tanaka, N., Kobayashi, H., Ishizuka, N., Minakuchi, H., Nakanishi, K., Hosoya, K., & Ikegami, T. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)01582-5 · Cited by 497
Separation efficiencies in hydrophilic interaction chromatography
Ikegami, T., Tomomatsu, K., Takubo, H., Horie, K., & Tanaka, N. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.01.075 · Cited by 419
The sol-gel encapsulation of enzymes
Pierre, A. C. (2004) · Biocatalysis and Biotransformation · doi:10.1080/10242420412331283314 · Cited by 384
Metadata
- Authors
- Fields, S. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-08-01
- Volume
- 68
- Issue
- 15
- Pages
- 2709-2712
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2022333071
- Cited by
- 174
- References
- 0
- FWCI
- 5.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Silica Xerogel as a Continuous Column Support for High-Performance Liquid Chromatography. https://app.cochat.ai/papers/10.1021/ac951247v
- The paper
- Fields, S. M. (1996). Silica Xerogel as a Continuous Column Support for High-Performance Liquid Chromatography. Analytical Chemistry. https://doi.org/10.1021/ac951247v
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.