The DOI matches its Crossref record.
Phosphopeptide Analysis by Matrix-Assisted Laser Desorption Time-of-Flight Mass Spectrometry
Abstract
In this paper we present methods for identifying and sequencing phosphopeptides in simple mixtures, such as HPLC fractions, at the subpicomole level by (+) ion matrix-assisted laser desorption time-of-flight mass spectrometry (MALDI-MS). Data are presented which indicate that when a reflectron time-of-flight mass spectrometer is used, MALDI can distinguish tyrosine phosphorylation from serine and threonine phosphorylation for peptides containing a single phosphate group. Phosphopeptides are identified in the (+) ion MALDI reflector spectrum by the presence of [MH-H3PO4]+ and [MH-HPO3]+ fragment ions formed by metastable decomposition. An abundant [MH-H3PO4]+ ion, accompanied by a weaker [MH-HPO3]+ ion indicates that the peptide is most likely phosphorylated on serine or threonine. In contrast, phosphotyrosine-containing peptides generally exhibit [MH-HPO3]+ fragment ions and little, if any [MH-H3PO4]+. Ambiguities do arise, most often with phosphopeptides that contain residues which readily lose water (such as unmodified serine), but these can often be resolved by recording a complete metastable fragment ion (postsource decay) spectrum. Postsource decay is shown here to be a viable technique for sequencing phosphopeptides. It can be used to distinguish between serine/ threonine and tyrosine phosphorylation and in many cases can be used to determine the exact site of phosphorylation in a peptide sequence. Nearly complete sequence coverage and phosphorylation site mapping is generally possible using approximately 300 fmol of peptide.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Immobilized Gallium(III) Affinity Chromatography of Phosphopeptides
Posewitz, M. C., & Tempst, P. (1999) · Analytical Chemistry · doi:10.1021/ac981409y · Cited by 832
Tanner, K. G., Landry, J., Sternglanz, R., & Denu, J. M. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.250422697 · Cited by 555
Zhao, J., Du, Y., Horton, J. R., Upadhyay, A. K., Lou, B., Bai, Y., Zhang, X., Du, L., Li, M., Wang, B., et al. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1100012108 · Cited by 105
Lim, A., Prokaeva, T., McComb, M. E., O'Connor, P. B., Théberge, R., Connors, L. H., Skinner, M., & Costello, C. E. (2002) · Analytical Chemistry · doi:10.1021/ac010780+ · Cited by 63
Metadata
- Authors
- Annan, R. S., & Carr, S. A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-10-01
- Volume
- 68
- Issue
- 19
- Pages
- 3413-3421
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2071106732
- Cited by
- 310
- References
- 0
- FWCI
- 9.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Phosphopeptide Analysis by Matrix-Assisted Laser Desorption Time-of-Flight Mass Spectrometry. https://app.cochat.ai/papers/10.1021/ac960221g
- The paper
- Annan, R. S., & Carr, S. A. (1996). Phosphopeptide Analysis by Matrix-Assisted Laser Desorption Time-of-Flight Mass Spectrometry. Analytical Chemistry. https://doi.org/10.1021/ac960221g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.