The DOI matches its Crossref record.
Noncovalent Polycationic Coatings for Capillaries in Capillary Electrophoresis of Proteins
Abstract
The adsorption of proteins with net positive charges (pI > pH) on the walls of fused-silica capillaries is a common problem in the analysis of proteins by capillary electrophoresis. This paper explores the use of polycationic polymers as noncovalent coatings to limit this problem. The behavior of three sets of proteins was compared using uncoated and coated capillaries: (i) a protein charge ladder obtained by acetylation of lysozyme (EC 3.2.1.17); (ii) a protein charge ladder obtained by acetylation of carbonic anhydrase II (EC 4.2.1.1); (iii) a test panel of proteins with a range of values of molecular weight and pI. Four polycationic polymers were examined: polyethylenimine (PEI; MWav = 15000), Polybrene (MWav = 25000), poly(methoxyethoxyethyl)ethylenimine (MWav = 64000), and poly(diallyldimethylammonium chloride) (MWav = 10000). Detection of proteins with high pI was readily achieved using the first three of these polycationic polymer coatings but not with the poly(diallyldimethyl-ammonium chloride). Examination of the stability of these coatings indicates that they are robust: the change in electroosmotic flow was less than 10% for 25 replications of the same separations, using capillaries coated with PEI or Polybrene. This study demonstrates that the charge ladder obtained by acetylation of lysozyme is a good model with which to test the efficiency of polycationic coatings. A study of the electrophoretic mobilities of the members of this charge ladder at pH 8.3 determined the effective charge of lysozyme (Zp(0) = +7.6 +/- 0.1) and established the acidity of the alpha-ammonium group of lysozyme (pKa = 7.8 +/- 0.1). Results from the test panel of proteins suggest that protein adsorption is mainly driven by electrostatic interactions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biological surface engineering: a simple system for cell pattern formation
Zhang, S., Yan, L., Altman, M., Lässle, M., Nugent, H., Frankel, F., Lauffenburger, D. A., Whitesides, G. M., & Rich, A. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00014-9 · Cited by 344
Self-citationNon-covalent capillary coatings for protein separations in capillary electrophoresis
Lucy, C. A., MacDonald, A. M., & Gulcev, M. D. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.114 · Cited by 299
Gitlin, I., Carbeck, J. D., & Whitesides, G. M. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200502530 · Cited by 286
Self-citationKatayama, H., Ishihama, Y., & Asakawa, N. (1998) · Analytical Chemistry · doi:10.1021/ac980522l · Cited by 264
Bush, D. R., Zang, L., Belov, A. M., Ivanov, A. R., & Karger, B. L. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b03218 · Cited by 92
Metadata
- Authors
- Córdova, E., Gao, J., & Whitesides, G. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-04-01
- Volume
- 69
- Issue
- 7
- Pages
- 1370-1379
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2051925947
- Cited by
- 207
- References
- 0
- FWCI
- 13.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noncovalent Polycationic Coatings for Capillaries in Capillary Electrophoresis of Proteins. https://app.cochat.ai/papers/10.1021/ac960432l
- The paper
- Córdova, E., Gao, J., & Whitesides, G. M. (1997). Noncovalent Polycationic Coatings for Capillaries in Capillary Electrophoresis of Proteins. Analytical Chemistry. https://doi.org/10.1021/ac960432l
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.