The DOI matches its Crossref record.
Mechanism of Signal Suppression by Anionic Surfactants in Capillary Electrophoresis−Electrospray Ionization Mass Spectrometry
Open accessAbstract
Micellar-mediated capillary electrophoresis (CE) is used for a wide variety of applications, including the separation of pharmaceuticals, environmental contaminants, illicit drugs, DNA fragments, and many other biological samples. The electrospray ionization interface is one of the most common CE-MS interfaces. Coupling micellar-mediated CE separations with MS detection combines two very powerful, widely applicable analytical techniques. Some types of surfactants strongly interfere with electrospray ionization mass spectrometric (ESI-MS) detection of analytes, and in many cases the ESI-MS analyte signals are completely quenched. Only a few reports have appeared that describe the ESI-MS detection of analytes in the presence of surfactants; however, the exact mechanism of ionization suppression has not yet been addressed. In this work, a modified aerosol ionic redistribution (AIR) model is presented that qualitatively explains the results of previous studies, including those using "polymeric surfactants". Analyte ionization suppression by surfactants appears to be caused by Coulombic interaction between oppositely charged solute and surfactant ions in the ESI-produced offspring droplets. It appears that the ability of surfactants to quench electrospray ionization is directly related to the surface activity and the charge of the surfactant. Also, highly surface active components tend to be enriched in ESI-produced offspring droplets. Analyte ion signals can be detected under conditions that lower the surface concentration of oppositely charged surfactant ions in aerosol droplets. The mechanistic information outlined here may be used to design micellar-mediated CE separations that allow detection of analyte ions by ESI-MS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hydrogen exchange mass spectrometry for studying protein structure and dynamics
Konermann, L., Pan, J., & Liu, Y.-H. (2011) · Chem. Soc. Rev. · doi:10.1039/c0cs00113a · Cited by 838
Micelles Protect Membrane Complexes from Solution to Vacuum
Barrera, N. P., Di Bartolo, N., Booth, P. J., & Robinson, C. V. (2008) · Science · doi:10.1126/science.1159292 · Cited by 360
Non-covalent capillary coatings for protein separations in capillary electrophoresis
Lucy, C. A., MacDonald, A. M., & Gulcev, M. D. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.114 · Cited by 299
Capillary electrophoresis – mass spectrometry: 15 years of developments and applications
Schmitt‐Kopplin, P., & Frommberger, M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305659 · Cited by 289
State-of-the-art in liquid chromatography–mass spectrometry
Niessen, W. M. A. (1999) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)00480-x · Cited by 267
Doucette, A. A., Vieira, D. B., Orton, D. J., & Wall, M. J. (2014) · Journal of Proteome Research · doi:10.1021/pr500864a · Cited by 63
Sánchez‐Hernández, L., Montealegre, C., Kiessig, S., Moritz, B., & Neusüß, C. (2017) · ELECTROPHORESIS · doi:10.1002/elps.201600464 · Cited by 29
Metadata
- Authors
- Rundlett, K. L., & Armstrong, D. W.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-10-01
- Volume
- 68
- Issue
- 19
- Pages
- 3493-3497
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2082554919
- Cited by
- 192
- References
- 0
- FWCI
- 1.94
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.