Miniaturized Supported Liquid Membrane Device for Selective On-Line Enrichment of Basic Drugs in Plasma Combined with Capillary Zone Electrophoresis
The DOI matches its Crossref record.
Abstract
A hollow fiber miniaturized supported liquid membrane (SLM) device for sample preparation is connected on-line with capillary electrophoresis and used for determination of a basic drug, bambuterol, in human plasma. The analyte is extracted from the outside of the hollow fiber (donor) through the liquid membrane (pores of the fiber impregnated with organic solvent) into the acceptor solution in the fiber lumen. The process is driven by differences in pH between the donor and acceptor solution. The whole volume of the acceptor solution can then be injected into the CZE capillary by using the double-stacking procedure for large volume-injection. Very clean extracts of low ionic strength are obtained from the SLM treatment, making this sample pretreatment method compatible with the CZE double-stacking procedure, which in turn makes it possible to inject large volumes of sample onto the separation capillary. Good performance of the whole procedure is demonstrated, and detection limits in the low nanomolar range were obtained in spite of the relatively weak UV absorbance of bambuterol. Extractions through the miniaturized SLM unit can be performed for 5-6 h without regenerating the fiber. The regeneration procedure was tested, and no relevant changes in the performance of the extraction could be found after seven regenerations, allowing the same fiber to be used for a week.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pedersen-Bjergaard, S., & Rasmussen, K. E. (1999) · Analytical Chemistry · doi:10.1021/ac990055n · Cited by 1,245
Developments in hollow fibre-based, liquid-phase microextraction
Rasmussen, K. E., & Pedersen-Bjergaard, S. (2004) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(04)00105-0 · Cited by 520
Methodologies for the Extraction of Phenolic Compounds from Environmental Samples: New Approaches
Mahugo Santana, C., Sosa Ferrera, Z., Esther Torres Padrón, M., & Juan Santana Rodríguez, J. (2009) · Molecules · doi:10.3390/molecules14010298 · Cited by 299
Membrane-based techniques for sample enrichment
Jönsson, J. Å., & Mathiasson, L. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00922-5 · Cited by 288
Self-citationMa, M., & Cantwell, F. F. (1999) · Analytical Chemistry · doi:10.1021/ac9805899 · Cited by 222
Metadata
- Authors
- Pálmarsdóttir, S., Thordarson, E., Edholm, L.-E., Jönsson, J. Å., & Mathiasson, L.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-05-01
- Volume
- 69
- Issue
- 9
- Pages
- 1732-1737
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2057813031
- Cited by
- 146
- References
- 0
- FWCI
- 9.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Miniaturized Supported Liquid Membrane Device for Selective On-Line Enrichment of Basic Drugs in Plasma Combined with Capillary Zone Electrophoresis. https://app.cochat.ai/papers/10.1021/ac960668p
- The paper
- Pálmarsdóttir, S., Thordarson, E., Edholm, L.-E., Jönsson, J. Å., & Mathiasson, L. (1997). Miniaturized Supported Liquid Membrane Device for Selective On-Line Enrichment of Basic Drugs in Plasma Combined with Capillary Zone Electrophoresis. Analytical Chemistry. https://doi.org/10.1021/ac960668p
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.