The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Sample Preparation Device for Quantitative Hydrogen Isotope Analysis Using Chromium Metal
Abstract
A new technique for the sample preparation, directly coupled to an isotope ratio mass spectrometer (IRMS) for D/H determination, is described. The method is suitable for the preparation of fresh and saline waters as well as different organic compounds (gaseous or liquid). One microliter of water or hydrogen equivalent is injected and reduced by means of chromium metal in a specially designed reaction furnace, and then the hydrogen gas flows directly into the IRMS to be analyzed by standard/sample comparison. The reproducibility is about 1‰. The accuracy of this method is confirmed by analysis of IAEA standard waters VSMOW, GISP, and SLAP. All aqueous samples including liquid food samples as well as methane gas were injected as original compounds and directly measured without any preparation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Standard for Reporting Concentrations of Deuterium and Oxygen-18 in Natural Waters
Craig, H. (1961) · Science · doi:10.1126/science.133.3467.1833 · Cited by 2,013
Cited by
Stable isotope fractionation analysis as a tool to monitor biodegradation in contaminated acquifers
Meckenstock, R. U., Morasch, B., Griebler, C., & Richnow, H. H. (2004) · Journal of Contaminant Hydrology · doi:10.1016/j.jconhyd.2004.06.003 · Cited by 438
Sharp, Z. D., Atudorei, V, & Durakiewicz, T. (2001) · Chemical Geology · doi:10.1016/s0009-2541(01)00262-5 · Cited by 334
Falk, E. S., Guo, W., Paukert, A. N., Matter, J. M., Mervine, E. M., & Kelemen, P. B. (2016) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2016.06.026 · Cited by 75
Metadata
- Authors
- Gehre, M., Hoefling, R., Kowski, P., & Strauch, G.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-01-01
- Volume
- 68
- Issue
- 24
- Pages
- 4414-4417
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2026702923
- Cited by
- 185
- References
- 1
- FWCI
- 2.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.