The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Nanometer-Sized Electrochemical Sensors
Abstract
Nanometer-sized glass-sealed metal ultramicroelectrodes (UMEs) have been prepared using a laser-based micropipet puller. The tip was exposed to solution either by etching away a small portion of glass insulator or by micropolishing. The characterization of the UMEs was carried out by a combination of steady-state voltammetry, scanning electron microscopy (SEM), and scanning electrochemical microscopy (SECM). The cyclic voltammograms obtained have a regular shape with very small capacitive and resistive background. The effective electrode radii obtained from voltammetry were between 2 and 500 nm. From the SEM micrographs, the shape of polished tips appears to be close to a microdisk, while the geometry of etched electrodes is closer to conical. Accordingly, the SECM current−distance curves ( i T − d ) obtained with polished electrodes fit well the theory for a disk-shaped tip, while a 20-nm-radius etched electrode was shown to be a fairly sharp cone with a height-to-radius ratio of about 2.5. The experimental data were compared to the theory developed for disk-shaped, conical, and recessed tips to demonstrate suitability of the produced electrodes for quantitative electrochemical experiments. The prospects of steady-state measurements of the rates of fast heterogeneous reactions are discussed. Submicrometer-sized ion selective electrodes (ISEs) were prepared by coating etched Ag tips with silver iodide. The concentration response of such ISEs remained stable and linear after coating of the ISEs with protective Nafion film.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fabrication and Evaluation of Nanoelectrode Ensembles
Menon, V. P., & Martin, C. R. (1995) · Analytical Chemistry · doi:10.1021/ac00109a003 · Cited by 698
Chronoamperometric current at finite disk electrodes
Shoup, D., & Szabo, A. (1982) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/0022-0728(82)85171-1 · Cited by 628
Fabrication and Use of Nanometer-Sized Electrodes in Electrochemistry
Penner, R. M., Heben, M. J., Longin, T. L., & Lewis, N. S. (1990) · Science · doi:10.1126/science.250.4984.1118 · Cited by 356
Simple analysis of quasi-reversible steady-state voltammograms
Mirkin, M. V., & Bard, A. J. (1992) · Analytical Chemistry · doi:10.1021/ac00043a020 · Cited by 247
Self-citationMicroelectrodes: new dimensions in electrochemistry
Forster, R. J. (1994) · Chemical Society Reviews · doi:10.1039/cs9942300289 · Cited by 246
Single Molecule Electrochemistry
Fan, F.-R. F., Kwak, J., & Bard, A. J. (1996) · Journal of the American Chemical Society · doi:10.1021/ja9610794 · Cited by 192
Comparison of voltammetric steady states at hemispherical and disc microelectrodes
Oldham, K. B., & Zoski, C. G. (1988) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/0022-0728(88)85002-2 · Cited by 178
Smith, C. P., & White, H. S. (1993) · Analytical Chemistry · doi:10.1021/ac00071a002 · Cited by 165
Zhang, X., Zhang, W., Zhou, X., & Ogorevc, B. (1996) · Analytical Chemistry · doi:10.1021/ac9600969 · Cited by 58
Smythe, W. R. (1953) · Journal of Applied Physics · doi:10.1063/1.1721136 · Cited by 44
Cited by
Perovskite Microdisk Microlasers Self‐Assembled from Solution
Liao, Q., Hu, K., Zhang, H., Wang, X., Yao, J., & Fu, H. (2015) · Advanced Materials · doi:10.1002/adma.201500449 · Cited by 406
Scanning electrochemical microscopy in the 21st century
Sun, P., Laforge, F. O., & Mirkin, M. V. (2007) · Phys. Chem. Chem. Phys. · doi:10.1039/b612259k · Cited by 310
Self-citationAccurate Simulations of Electric Double Layer Capacitance of Ultramicroelectrodes
Wang, H., & Pilon, L. (2011) · The Journal of Physical Chemistry C · doi:10.1021/jp204498e · Cited by 307
Zhang, B., Galusha, J., Shiozawa, P. G., Wang, G., Bergren, A. J., Jones, R. M., White, R. J., Ervin, E. N., Cauley, C. C., & White, H. S. (2007) · Analytical Chemistry · doi:10.1021/ac070609j · Cited by 277
Metadata
- Authors
- Shao, Y., Mirkin, M. V., Fish, G., Kokotov, S., Palanker, D., & Lewis, A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-04-01
- Volume
- 69
- Issue
- 8
- Pages
- 1627-1634
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2079142905
- Cited by
- 262
- References
- 10
- FWCI
- 6.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nanometer-Sized Electrochemical Sensors. https://app.cochat.ai/papers/10.1021/ac960887a
- The paper
- Shao, Y., Mirkin, M. V., Fish, G., Kokotov, S., Palanker, D., & Lewis, A. (1997). Nanometer-Sized Electrochemical Sensors. Analytical Chemistry. https://doi.org/10.1021/ac960887a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.