The DOI matches its Crossref record.
UV Laser Machined Polymer Substrates for the Development of Microdiagnostic Systems
Open accessAbstract
This report describes a UV laser photoablation method for the production of miniaturized liquid-handling systems on polymer substrate chips. The fabrication of fluid channel and reservoir networks is accomplished by firing 200 mJ pulses from an UV excimer laser at substrates moving in predefined computer-controlled patterns. This method was used for producing channels in polystyrene, polycarbonate, cellulose acetate, and poly(ethylene terephthalate). Efficient sealing of the resulting photoablated polymer channels was accomplished using a low-cost film lamination technique. After fabrication, the ablated structures were observed to be well defined, i.e., possessing high aspect ratios, as seen by light, scanning electron, and atomic force microscopy. Relative to the original polymer samples, photoablated surfaces showed an increase in their hydrophilicity and rugosity as a group, yet differences were noted between the polymers studied. These surface characteristics demonstrate the capability of generating electroosmotic flow in the cathodic direction, which is characterized here as a function of applied electric field, pH, and ionic strength of common electrophoretic buffer systems. These results show a correlation between the ablative changes in surface conditions and the resulting electroosmotic flow. The effect of protein coatings on ablated surfaces is also demonstrated to significantly dampen the electroosmotic flow for all polymers. All of these results are discussed in terms of developing liquid-handling capability, which is an essential part of many μ-TAS and chemical diagnostic systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Abgrall, P., & Gué, A.-M. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/17/5/r01 · Cited by 561
Verpoorte, E., & De Rooij, N. F. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.813570 · Cited by 503
Klank, H., Kutter, J. P., & Geschke, O. (2002) · Lab on a Chip · doi:10.1039/b206409j · Cited by 477
An Integrated Fluorescence Detection System in Poly(dimethylsiloxane) for Microfluidic Applications
Chabinyc, M. L., Chiu, D. T., McDonald, J. C., Stroock, A. D., Christian, J. F., Karger, A. M., & Whitesides, G. M. (2001) · Analytical Chemistry · doi:10.1021/ac010423z · Cited by 419
Metadata
- Authors
- Roberts, M. A., Rossier, J. S., Bercier, P., & Girault, H.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-06-01
- Volume
- 69
- Issue
- 11
- Pages
- 2035-2042
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1988654953
- Cited by
- 497
- References
- 0
- FWCI
- 20.44
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: UV Laser Machined Polymer Substrates for the Development of Microdiagnostic Systems. https://app.cochat.ai/papers/10.1021/ac961038q
- The paper
- Roberts, M. A., Rossier, J. S., Bercier, P., & Girault, H. (1997). UV Laser Machined Polymer Substrates for the Development of Microdiagnostic Systems. Analytical Chemistry. https://doi.org/10.1021/ac961038q
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.