The DOI matches its Crossref record.
Current Rectification at Quartz Nanopipet Electrodes
Abstract
Ag/AgCl reference electrodes fabricated from pulled quartz tubes with orifice radii of 20 nm to 20 μm were characterized in KCl solutions of different concentrations by cyclic voltammetry. Linear current−voltage ( i − V ) dependence was observed with micropipet electrodes (with micrometer-sized tips) with the same concentration (0.01−1 M) of KCl inside and outside the pipet, but current rectification was found at nanopipet electrodes at KCl concentrations of ≤0.1 M (with nanometer-sized tips). This is attributed to formation of a diffuse electrical double layer within the tip orifice. The effects of electrode size, electrolyte concentration, and solution pH on the nonlinear i − V behavior of these electrodes were investigated. A model for the observed behavior shows the rectification to be caused by the permselectivity in the tip region and the geometric asymmetry of the tip orifice. This phenomenon may be important in studies of ion transport in charged channels and porous membranes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Critical Knowledge Gaps in Mass Transport through Single-Digit Nanopores: A Review and Perspective
Faucher, S., Aluru, N., Bazant, M. Z., Blankschtein, D., Brozena, A. H., Cumings, J., Pedro de Souza, J., Elimelech, M., Epsztein, R., Fourkas, J. T., et al. (2019) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.9b02178 · Cited by 365
Zhang, B., Galusha, J., Shiozawa, P. G., Wang, G., Bergren, A. J., Jones, R. M., White, R. J., Ervin, E. N., Cauley, C. C., & White, H. S. (2007) · Analytical Chemistry · doi:10.1021/ac070609j · Cited by 277
Tuning Transport Properties of Nanofluidic Devices with Local Charge Inversion
He, Y., Gillespie, D., Boda, D., Vlassiouk, I., Eisenberg, R. S., & Siwy, Z. S. (2009) · Journal of the American Chemical Society · doi:10.1021/ja808717u · Cited by 268
Metadata
- Authors
- Wei, C., Bard, A. J., & Feldberg, S. W.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-11-01
- Volume
- 69
- Issue
- 22
- Pages
- 4627-4633
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2068973343
- Cited by
- 576
- References
- 0
- FWCI
- 2.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.