The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Macroporous Polyacrylamide/Poly(ethylene glycol) Matrixes as Stationary Phases in Capillary Electrochromatography
Abstract
A one-step method is described for in situ preparation of macroporous polymeric matrixes to be used as stationary phases for capillary electrochromatography. The monomers (acrylamide, bisacrylamide, and acrylic or vinylsulfonic acid), including hydrophobic ligands (C 4, C 6, or C 12 ), and poly(ethylene glycol) have been polymerized in formamide (or N -methylformamide) aqueous solutions inside the capillary. The capillary wall had been activated first by a bifunctional reagent, to couple covalently the resulting gel inside the fused-silica tubing. Thus, no frit is necessary to keep the stationary phase in place. High efficiencies were obtained for a mixture of alkyl phenones (up to 398 000 plates/m). Good separations are achieved in less than 5 min. The migration time reproducibility is better than 1% (RSD) from run to run and 2.5% from day to day. The gel is stable up to at least 50% acetonitrile used as a mobile phase. On-column UV and fluorescence detection can readily be employed. Applications to peptides and carbohydrates are also shown.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DISC ELECTROPHORESIS – II METHOD AND APPLICATION TO HUMAN SERUM PROTEINS*
Davis, B. J. (1964) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1964.tb14213.x · Cited by 18,892
DISC ELECTROPHORESIS‐I BACKGROUND AND THEORY*
Ornstein, L. (1964) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1964.tb14207.x · Cited by 4,565
High-performance electrophoresis
Hjertén, S. (1985) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)95485-8 · Cited by 1,513
Electrokinetic chromatography with micellar solution and open-tubular capillary
Terabe, S., Otsuka, K., & Ando, T. (1985) · Analytical Chemistry · doi:10.1021/ac00281a014 · Cited by 1,195
The spaces in a uniform random suspension of fibres
Ogston, A. G. (1958) · Transactions of the Faraday Society · doi:10.1039/tf9585401754 · Cited by 1,058
High-resolution separations based on electrophoresis and electroosmosis
Jorgenson, J. W., & Lukacs, K. D. (1981) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)82057-9 · Cited by 858
Bigge, J. C., Patel, T. P., Bruce, J. A., Goulding, P. N., Charles, S. M., & Parekh, R. B. (1995) · Analytical Biochemistry · doi:10.1006/abio.1995.1468 · Cited by 825
Schwer, C., & Kenndler, E. (1991) · Analytical Chemistry · doi:10.1021/ac00017a026 · Cited by 529
Transmission-electron microscopic observations of freeze-etched polyacrylamide gels
Rüchel, R., Steere, R. L., & Erbe, E. F. (1978) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)95641-3 · Cited by 104
Characterization of Surfactant Selectivity in Micellar Electrokinetic Chromatography
Poole, S. K., & Poole, C. F. (1997) · The Analyst · doi:10.1039/a605799c · Cited by 91
Microcolumn liquid chromatography of benzoyl derivatives of steroid metabolites
Novotný, M. V., Alasandro, M. S., & Konishi, M. (1983) · Analytical Chemistry · doi:10.1021/ac00264a038 · Cited by 42
Cited by
Monolithic columns in high-performance liquid chromatography
Guiochon, G. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.090 · Cited by 831
Porous polymer monoliths: Amazingly wide variety of techniques enabling their preparation
Svec, F. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.09.073 · Cited by 577
Monolithic silica columns for high-efficiency chromatographic separations
Tanaka, N., Kobayashi, H., Ishizuka, N., Minakuchi, H., Nakanishi, K., Hosoya, K., & Ikegami, T. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)01582-5 · Cited by 497
Template-Directed Preparation of Macroporous Polymers with Oriented and Crystalline Arrays of Voids
Jiang, P., Hwang, K. S., Mittleman, D. M., Bertone, J. F., & Colvin, V. L. (1999) · Journal of the American Chemical Society · doi:10.1021/ja9903476 · Cited by 373
Monolithic stationary phases for liquid chromatography and capillary electrochromatography
Zou, H., Huang, X., Ye, M., & Luo, Q. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)00072-9 · Cited by 364
Metadata
- Authors
- Palm, A., & Novotny, M. V.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-11-01
- Volume
- 69
- Issue
- 22
- Pages
- 4499-4507
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2051651683
- Cited by
- 328
- References
- 11
- FWCI
- 14.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources