The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Solvent Microextraction with Simultaneous Back-Extraction for Sample Cleanup and Preconcentration: Quantitative Extraction
Abstract
A solvent microextraction technique has been developed to perform simultaneous forward- and back-extraction across a microliter-size organic liquid membrane. The organic liquid membrane phase (o), consisting of 40 or 80 μL of n -octane, is layered over 0.5 or 1.0 mL of aqueous sample phase (a1) contained in a 1- or 2-mL microreaction vial and is stabilized against mechanical disruption by a small Teflon ring, even when the a1 phase is stirred at a speed of 2000 rpm. A 0.1- or 0.2-mL aqueous receiving phase (a2) is layered over the o phase. After extraction for a prescribed time, an aliquot of the a2 phase is injected directly into an HPLC for quantification. The technique is efficient and selective for ionizable compounds. In 30 min, the model compounds, mephentermine and 2-phenylethylamine, in the a1 phase buffered at pH 13 are 100% and 90% extracted, respectively, into the a2 phase buffered at pH 2.1. A kinetic model has been developed, based on the Whitman two-film theory, to describe the extraction process and has been verified experimentally. The technique is promising for routine applications because of its simplicity, reproducibility, selectivity, overall sample preparation time, and quantitative extraction of compounds with relatively small distribution coefficients with submilliliter volumes of aqueous back-extractant.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Self-citation
Cited by
Pedersen-Bjergaard, S., & Rasmussen, K. E. (1999) · Analytical Chemistry · doi:10.1021/ac990055n · Cited by 1,245
Armenta, S., Garrigues, S., & de la Guardia, M. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2008.05.003 · Cited by 1,213
Developments in liquid-phase microextraction
Psillakis, E., & Kalogerakis, N. (2003) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(03)01007-0 · Cited by 608
Developments in hollow fibre-based, liquid-phase microextraction
Rasmussen, K. E., & Pedersen-Bjergaard, S. (2004) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(04)00105-0 · Cited by 520
A new liquid-phase microextraction method based on solidification of floating organic drop
Khalili Zanjani, M. R., Yamini, Y., Shariati, S., & Jönsson, J. Å. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.12.049 · Cited by 512
Metadata
- Authors
- Ma, M., & Cantwell, F. F.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-08-14
- Volume
- 70
- Issue
- 18
- Pages
- 3912-3919
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2058666544
- Cited by
- 167
- References
- 1
- FWCI
- 4.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.