The DOI matches its Crossref record.
Determination of Cyanide in Whole Blood by Capillary Gas Chromatography with Cryogenic Oven Trapping
Abstract
Cyanide, one of the most important toxic substances, has been found measurable with high sensitivity by capillary gas chromatography (GC) with cryogenic oven trapping upon injection of headspace (HS) vapor samples. The entire amount of cyanide in the HS sample could be cryogenically trapped prior to on-line GC analysis. A 0.5-mL volume of blood in the presence or absence of cyanide and propionitrile (internal standard, IS) was added to a vial containing 0.25 mL of distilled water, 0.3 g of Na2-SO4, 0.2 mL of 50% H3PO4, and 0.1 g of ascorbic acid (when needed), and the mixture was heated at 70 degrees C for 15 min. A 5-mL volume of the HS vapor was introduced into a GC capillary column in the splitless mode at -30 degrees C oven temperature that was programmed up to 160 degrees C for GC analysis with nitrogen-phosphorus detection. A sharp peak was obtained for cyanide under the present conditions, and backgrounds were very clean. The extraction efficiencies of cyanide and IS were 2.89-3.22 (100 or 500 ng/mL) and 2.42%, respectively. The calibration curve showed good linearity in the range of 25-1000 ng/mL and the detection limit was approximately 2 ng/mL. The coefficients of intraday and interday variations were 2.9 and 11.8%, respectively. The mean blood cyanide level measured for actual fire victims was 687 +/- 597 ng/mL (mean +/- SD, n = 9). Endogenous blood cyanide concentration for healthy subjects was 8.41 +/- 3.09 ng/mL (mean +/- SD, n = 6).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Aggregation-Induced Emission: Together We Shine, United We Soar!
Mei, J., Leung, N. L. C., Kwok, R. T. K., Lam, J. W. Y., & Tang, B. Z. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00263 · Cited by 8,270
Sub-nanometre sized metal clusters: from synthetic challenges to the unique property discoveries
Lu, Y., & Chen, W. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15325d · Cited by 1,152
Cooper, C. E., & Brown, G. C. (2008) · Journal of Bioenergetics and Biomembranes · doi:10.1007/s10863-008-9166-6 · Cited by 718
Ekmekci, Z., Yilmaz, M. D., & Akkaya, E. U. (2008) · Organic Letters · doi:10.1021/ol702823u · Cited by 302
Metadata
- Authors
- Ishii, A., Seno, H., Watanabe-Suzuki, K., Suzuki, O., & Kumazawa, T.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-10-15
- Volume
- 70
- Issue
- 22
- Pages
- 4873-4876
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2067606668
- Cited by
- 163
- References
- 0
- FWCI
- 2.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of Cyanide in Whole Blood by Capillary Gas Chromatography with Cryogenic Oven Trapping. https://app.cochat.ai/papers/10.1021/ac980498b
- The paper
- Ishii, A., Seno, H., Watanabe-Suzuki, K., Suzuki, O., & Kumazawa, T. (1998). Determination of Cyanide in Whole Blood by Capillary Gas Chromatography with Cryogenic Oven Trapping. Analytical Chemistry. https://doi.org/10.1021/ac980498b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.