The DOI matches its Crossref record.
Solvent Microextraction with Simultaneous Back-Extraction for Sample Cleanup and Preconcentration: Preconcentration into a Single Microdrop
Abstract
A preconcentration technique which employs a microliter-size liquid membrane has been developed in order to obtain a large enrichment factor (EF) in a short time. The 30-μL n -octane liquid membrane, confined inside a small Teflon ring, is layered over 1.60 mL of aqueous source phase (sample), which is buffered at pH 13. The receiving phase is either a 1.0 0 - or a 0.50-μL aqueous drop buffered at pH 2.1, that is suspended in the 30-μL membrane phase directly from the tip of a microsyringe needle. When the sample solution is stirred, basic analytes are extracted into the organic membrane phase and back-extracted simultaneously into the microdrop because they are neutral at high pH and protonated at low pH. After extracting for a prescribed time, the microdrop is taken back into the syringe needle and injected directly into an HPLC for quantification. In 15 min, the EFs in the 1.0 0 -μL receiving drop are about 500 for methamphetamine, mephentermine, and methoxyphenamine, and about 160 for 2-phenylethylamine. Enrichment factors are approximately doubled for the same 15-min extraction time by using a 0.50-μL receiving drop. The reasons for this significant increase in EF with decreasing drop volume are discussed on the basis of a previously derived kinetic model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sarafraz-Yazdi, A., & Amiri, A. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.10.003 · Cited by 779
Developments in liquid-phase microextraction
Psillakis, E., & Kalogerakis, N. (2003) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(03)01007-0 · Cited by 608
Developments in hollow fibre-based, liquid-phase microextraction
Rasmussen, K. E., & Pedersen-Bjergaard, S. (2004) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(04)00105-0 · Cited by 520
Lord, H., & Pawliszyn, J. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00836-0 · Cited by 468
Pena-Pereira, F., Lavilla, I., & Bendicho, C. (2009) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2008.10.042 · Cited by 414
Lee, J., Lee, H. K., Rasmussen, K. E., & Pedersen-Bjergaard, S. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.06.050 · Cited by 398
Developments in single-drop microextraction
Psillakis, E., & Kalogerakis, N. (2002) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(01)00126-1 · Cited by 373
Breadmore, M. C., Shallan, A. I., Rabanes, H. R., Gstoettenmayr, D., Abdul Keyon, A. S., Gaspar, A., Dawod, M., & Quirino, J. P. (2013) · ELECTROPHORESIS · doi:10.1002/elps.201200396 · Cited by 372
Sample preparation techniques for the determination of trace residues and contaminants in foods
Ridgway, K., Lalljie, S. P. D., & Smith, R. M. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.01.134 · Cited by 354
Liquid-phase microextraction – The different principles and configurations
Yamini, Y., Rezazadeh, M., & Seidi, S. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.06.010 · Cited by 309
Dadfarnia, S., & Haji Shabani, A. M. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.11.022 · Cited by 305
Critical overview of selected contemporary sample preparation techniques
Ramos, L. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.11.011 · Cited by 280
Recent developments in solid-phase microextraction coatings and related techniques
Dietz, C., Sanz, J., & Cámara, C. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.11.041 · Cited by 280
Single drop microextraction—Development, applications and future trends
Jeannot, M. A., Przyjazny, A., & Kokosa, J. M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.10.089 · Cited by 276
Liquid-phase microextraction techniques within the framework of green chemistry
Pena-Pereira, F., Lavilla, I., & Bendicho, C. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.02.016 · Cited by 221
Tang, S., Qi, T., Ansah, P. D., Nalouzebi Fouemina, J. C., Shen, W., Basheer, C., & Lee, H. K. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.09.016 · Cited by 195
Mohamadi, M., & Mostafavi, A. (2010) · Talanta · doi:10.1016/j.talanta.2009.12.004 · Cited by 91
Xia, L., Hu, B., & Wu, Y. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.09.089 · Cited by 81
Liquid-Phase Microextraction in Bioanalytical Sample Preparation
Lucena, R., Cruz-Vera, M., Cárdenas, S., & Valcárcel, M. (2009) · Bioanalysis · doi:10.4155/bio.09.16 · Cited by 55
Single-Drop Microextraction in Bioanalysis
Choi, K., Kim, J., & Chung, D. S. (2011) · Bioanalysis · doi:10.4155/bio.11.3 · Cited by 42
Metadata
- Authors
- Ma, M., & Cantwell, F. F.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-12-12
- Volume
- 71
- Issue
- 2
- Pages
- 388-393
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1998076926
- Cited by
- 222
- References
- 0
- FWCI
- 3.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.