Accelerated Solvent Extraction of Semivolatile Organic Compounds from Biomonitoring Samples of Pine Needles and Mosses
The DOI matches its Crossref record.
Abstract
Accelerated solvent extraction (ASE) was used for the simultaneous extraction of semivolatile organic compounds (SOCs) including chlorobenzenes (1,2,3,4-tetra-, penta-, hexachlorobenzene), HCH isomers ( α-, β-, γ-, δ-, ε-HCH), DDX ( p, p ‘-DDT, -DDE, -DDD), PCB congeners (28, 52, 101, 138, 153, 180), and PAHs (phenanthrene, anthracene, fluoranthene, pyrene, benzo[ a ]pyrene) from mosses ( Pleurozium schreberi ) growing in regional locations (central Germany) and pine needles ( Pinus sylvestris L.) from southern Russia (near the Caspian Sea). The results were compared with those obtained by ultrasonic extraction (USE). Using mixed moss samples (thorough cleanup, only minor interference during GC/MSD analysis) from one location mainly served to optimize two parameters, extraction solvent and temperature. The most favorable extraction conditions proved to be n -hexane as the extraction solvent, two temperature stages of 40 and 120 °C, a pressure of 15 MPa, and three static cycles in each case. These conditions were then applied to the extraction of SOCs from the wax and the inner pine needle fraction, which beforehand had undergone extractive separation with dichloromethane. ASE was found to be especially advantageous in the case of higher multiple exposures to pollutants and the resultant complicated matrixes (oleiferous extracts, pollutant/matrix conjugates). Owing to the much better separation of analyte/matrix, in many cases increases of 1−2 orders of magnitude were obtained in the analytical values of the contaminated sample materials compared to those obtained with USE.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Brack, W. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2139-z · Cited by 438
Ramos, L., Kristenson, E. M., & Brinkman, U. A. T. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)01336-5 · Cited by 415
Pressurised liquid extraction of persistent organic pollutants in environmental analysis
Björklund, E., Nilsson, T., & Bøwadt, S. (2000) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(00)00002-9 · Cited by 252
Hong, J., Kim, H.-Y., Kim, D.-G., Seo, J., & Kim, K.-J. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.03.003 · Cited by 96
Ratola, N., Alves, A., Kalogerakis, N., & Psillakis, E. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.04.054 · Cited by 49
Metadata
- Authors
- Wenzel, K.-D., Hubert, A., Manz, M., Weissflog, L., Engewald, W., & Schüürmann, G.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-10-17
- Volume
- 70
- Issue
- 22
- Pages
- 4827-4835
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2051652382
- Cited by
- 85
- References
- 0
- FWCI
- 5.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accelerated Solvent Extraction of Semivolatile Organic Compounds from Biomonitoring Samples of Pine Needles and Mosses. https://app.cochat.ai/papers/10.1021/ac9806299
- The paper
- Wenzel, K.-D., Hubert, A., Manz, M., Weissflog, L., Engewald, W., & Schüürmann, G. (1998). Accelerated Solvent Extraction of Semivolatile Organic Compounds from Biomonitoring Samples of Pine Needles and Mosses. Analytical Chemistry. https://doi.org/10.1021/ac9806299
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.