Abstract
The rapid lifetime determination method (RLD) is a mathematical technique for extremely rapid evaluations of lifetimes in exponential decays. It has been applied in luminescence microscopy and single-molecule lifetime evaluation. To date, the primary application has been in single-exponential evaluations. We present extensions of the method to double exponentials. Using Monte Carlo simulations, we assess the performance of both the double-exponential decay with known lifetimes and the double-exponential decay with unknown preexponential factors and lifetimes. Precision is evaluated as a function of the noise level (Poisson statistics), the ratios of the lifetimes, the ratios of their preexponential factors, and the fitting window. Optimum measurement conditions are determined. RLD is shown to work well over a wide range of practical experimental conditions. If the lifetimes are known, the preexponential factors can be determined with good precision even at low total counts (10(4)). With unknown preexponential factors and lifetimes, precisions decrease but are still acceptable. A new gating scheme (overlapped gating) is shown to offer improved precision for the case of a single-exponential decay. Theoretical predictions are tested against actual experimental data from a laser-based lifetime instrument.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Art of Fluorescence Imaging with Chemical Sensors
Schäferling, M. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201105459 · Cited by 721
Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications
Steinegger, A., Wolfbeis, O. S., & Borisov, S. M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00451 · Cited by 622
Thermographic phosphors for thermometry: A survey of combustion applications
Aldén, M., Omrane, A., Richter, M., & Särner, G. (2011) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2010.07.001 · Cited by 325
Demas, J. N., & DeGraff, B. A. (2001) · Coordination Chemistry Reviews · doi:10.1016/s0010-8545(00)00278-2 · Cited by 283
Self-citationPeer Reviewed: Oxygen Sensors Based on Luminescence Quenching.
Demas, J. N., DeGraff, B. A., & Coleman, P. B. (1999) · Analytical Chemistry · doi:10.1021/ac9908546 · Cited by 263
Self-citation
Metadata
- Authors
- Sharman, K. K., Periasamy, A., Ashworth, H., & Demas, J. N.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-01-20
- Volume
- 71
- Issue
- 5
- Pages
- 947-952
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2085362809
- Cited by
- 186
- References
- 0
- FWCI
- 3.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Error Analysis of the Rapid Lifetime Determination Method for Double-Exponential Decays and New Windowing Schemes. https://app.cochat.ai/papers/10.1021/ac981050d
- The paper
- Sharman, K. K., Periasamy, A., Ashworth, H., & Demas, J. N. (1999). Error Analysis of the Rapid Lifetime Determination Method for Double-Exponential Decays and New Windowing Schemes. Analytical Chemistry. https://doi.org/10.1021/ac981050d
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.