The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Experimental Comparison of the Different Approaches To Estimate LOD and LOQ of an HPLC Method
Abstract
Detection and quantification limits (LOD and LOQ) are two fundamental elements of method validation. Rigorous statistical definitions exist, but in HPLC they could not be implemented. Nevertheless there are several estimation methods for these limits. The most commonly used is the signal-to-noise ratio criterion. Others are based on the dispersion characteristics of the regression line, either simple or weighted. For LOQ, Eurachem proposed an alternate approach based on the use of a target value for the area RSD. Since official guidelines imposed no particular modus operandi, an experimental methodology was set up to investigate the compatibility of the different approaches and their respective reliabilities. Several samples prepared in a concentration range close to the limits were analyzed. It appeared that, both for values and their reliabilities, the different approaches were far from equivalent. In our opinion, the best way to handle the problem of detection and quantification limits was a methodology based on the use of the residual standard deviation of a weighted regression for LOD and on a Eurachem approach for LOQ. Values obtained by these means had the advantage of being reliable, i.e., with a small dispersion, and were still compatible with those obtained with the usual signal-to-noise ratio approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Currie, L. A. (1995) · Pure and Applied Chemistry · doi:10.1351/pac199567101699 · Cited by 1,703
Statistics for analytical chemistry
Nielsen, E. (1987) · Forensic Science International · doi:10.1016/0379-0738(87)90151-4 · Cited by 1,028
Peer Reviewed: A Practical Guide to Analytical Method Validation
Green, J. M. (1996) · Analytical Chemistry · doi:10.1021/ac961912f · Cited by 510
Interlaboratory Variability in Trace Element Analysis
Boyer, K. W., Horwitz, W., & Albert, R. H. (1985) · Analytical Chemistry · doi:10.1021/ac50001a031 · Cited by 121
Vial, J., Ménier, I., Jardy, A., Amger, P., Brun, A., & Burbaud, L. (1998) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(97)00668-3 · Cited by 17
Self-citation
Cited by
Persistent organic pollutants carried by synthetic polymers in the ocean environment
Rios, L. M., Moore, C., & Jones, P. R. (2007) · Marine Pollution Bulletin · doi:10.1016/j.marpolbul.2007.03.022 · Cited by 953
Backe, W. J., Day, T. C., & Field, J. A. (2013) · Environmental Science & Technology · doi:10.1021/es3034999 · Cited by 611
Analysis of recent pharmaceutical regulatory documents on analytical method validation
Rozet, E., Ceccato, A., Hubert, C., Ziemons, E., Oprean, R., Rudaz, S., Boulanger, B., & Hubert, P. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.03.111 · Cited by 266
González, O., Blanco, M. E., Iriarte, G., Bartolomé, L., Maguregui, M. I., & Alonso, R. M. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.03.077 · Cited by 253
Closing the Mass Balance on Fluorine on Papers and Textiles
Robel, A. E., Marshall, K., Dickinson, M., Lunderberg, D., Butt, C., Peaslee, G., Stapleton, H. M., & Field, J. A. (2017) · Environmental Science & Technology · doi:10.1021/acs.est.7b02080 · Cited by 182
Metadata
- Authors
- Vial, J., & Jardy, A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-06-12
- Volume
- 71
- Issue
- 14
- Pages
- 2672-2677
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2075927648
- Cited by
- 356
- References
- 5
- FWCI
- 7.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.