Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 356

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Experimental Comparison of the Different Approaches To Estimate LOD and LOQ of an HPLC Method

Vial, Jérôme, Jardy, Alain·1999·Analytical Chemistry

Abstract

Detection and quantification limits (LOD and LOQ) are two fundamental elements of method validation. Rigorous statistical definitions exist, but in HPLC they could not be implemented. Nevertheless there are several estimation methods for these limits. The most commonly used is the signal-to-noise ratio criterion. Others are based on the dispersion characteristics of the regression line, either simple or weighted. For LOQ, Eurachem proposed an alternate approach based on the use of a target value for the area RSD. Since official guidelines imposed no particular modus operandi, an experimental methodology was set up to investigate the compatibility of the different approaches and their respective reliabilities. Several samples prepared in a concentration range close to the limits were analyzed. It appeared that, both for values and their reliabilities, the different approaches were far from equivalent. In our opinion, the best way to handle the problem of detection and quantification limits was a methodology based on the use of the residual standard deviation of a weighted regression for LOD and on a Eurachem approach for LOQ. Values obtained by these means had the advantage of being reliable, i.e., with a small dispersion, and were still compatible with those obtained with the usual signal-to-noise ratio approach.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac981179n

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 356

Metadata

Authors
Vial, J., & Jardy, A.
Venue
Analytical Chemistry
Published
1999-06-12
Volume
71
Issue
14
Pages
2672-2677
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2075927648
Cited by
356
References
5
FWCI
7.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.