The DOI matches its Crossref record.
Electrospray Ionization High-Field Asymmetric Waveform Ion Mobility Spectrometry−Mass Spectrometry
Abstract
High-field asymmetric waveform ion mobility spectrometry (FAIMS) is a new technique that separates gas-phase ions at atmospheric pressure (760 Torr) and room temperature. A FAIMS instrument acts as an ion filter and can be set to continuously transmit one type of ion. Despite the stringent requirement for a flow of clean, dry gas in the FAIMS analyzer region, a method of coupling electrospray to FAIMS has been developed. The identity of the electrospray ions separated by FAIMS was determined using mass spectrometry (FAIMS-MS). The theory of FAIMS is discussed, and electrospray FAIMS-MS spectra of several compounds in modes P1, P2, N1, and N2 are presented. Ions appearing in P1 and N1 modes tend to have mobilities that increase as a function of increasing electric field strength, whereas ions appearing in P2 and N2 modes tend to have mobilities that decrease. In general, low-mass ions are focused in P1 and N1 modes, whereas larger ions (e.g., proteins) are focused in P2 and N2 modes. Short-chain peptides, (Gly)(n) where n = 1-6, are shown to cross over from P1 mode into P2 mode as the chain length increases. The removal of the low-mass solvent cluster ions, combined with a reduction of the background noise in electrospray FAIMS-MS, results in an improved signal-to-noise ratio for mass spectra of larger ions (e.g., cyctochrome c) when compared with conventional electrospray-MS. Preliminary results also suggest that various charge states of cytochrome c can be distinguished by FAIMS, implying that the ion mobility of these species at high electric field strength is sensitive to the structure of the protein ion. The linearity of response of electrospray FAIMS-MS was investigated using leucine enkephalin and shows the calibration curve to be linear for ∼3 orders of magnitude.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lanucara, F., Holman, S. W., Gray, C. J., & Eyers, C. E. (2014) · Nature Chemistry · doi:10.1038/nchem.1889 · Cited by 901
A review of the occurrence, analyses, toxicity, and biodegradation of naphthenic acids
Clemente, J. S., & Fedorak, P. M. (2005) · Chemosphere · doi:10.1016/j.chemosphere.2005.02.065 · Cited by 591
Ion mobility mass spectrometry of proteins and proteinassemblies
Uetrecht, C., Rose, R. J., van Duijn, E., Lorenzen, K., & Heck, A. J. R. (2010) · Chem. Soc. Rev. · doi:10.1039/b914002f · Cited by 462
High-field asymmetric waveform ion mobility spectrometry: A new tool for mass spectrometry
Guevremont, R. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.08.119 · Cited by 444
Self-citationIon Mobility Spectrometry: Principles and Applications
Borsdorf, H., & Eiceman, G. A. (2006) · Applied Spectroscopy Reviews · doi:10.1080/05704920600663469 · Cited by 395
Metadata
- Authors
- Purves, R. W., & Guevremont, R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-05-19
- Volume
- 71
- Issue
- 13
- Pages
- 2346-2357
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1980427396
- Cited by
- 265
- References
- 0
- FWCI
- 6.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrospray Ionization High-Field Asymmetric Waveform Ion Mobility Spectrometry−Mass Spectrometry. https://app.cochat.ai/papers/10.1021/ac981380y
- The paper
- Purves, R. W., & Guevremont, R. (1999). Electrospray Ionization High-Field Asymmetric Waveform Ion Mobility Spectrometry−Mass Spectrometry. Analytical Chemistry. https://doi.org/10.1021/ac981380y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.