The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
A Fluorescence-Based Glucose Biosensor Using Concanavalin A and Dextran Encapsulated in a Poly(ethylene glycol) Hydrogel
Abstract
A fluorescence biosensor is described that is based on a photopolymerized poly(ethylene glycol) (PEG) hydrogel incorporating fluorescein isothiocyanate dextran (FITC-dextran) and tetramethylrhodamine isothiocyanate concanavalin A (TRITC-Con A) chemically conjugated into the hydrogel network using an alpha-acryloyl, omega-N-hydroxysuccinimidyl ester of PEG-propionic acid. In the absence of glucose, TRITC-Con A binds with FITC-dextran, and the FITC fluorescence is quenched through fluorescence resonance energy transfer. Competitive glucose binding to TRITC-Con A liberates FITC-dextran, resulting in increased FITC fluorescence proportional to the glucose concentration. In vitro experiments of hydrogel spheres in a solution of 0.1 M phosphate-buffered saline (pH 7.2) and glucose were conducted for multiple TRITC-Con A/FITC-dextran ratios. Hydrogels were characterized on the basis of the percent change in fluorescence intensity when FITC-dextran was liberated by increasing glucose concentrations. The optimum fluorescent change between 0 and 800 mg/dL was obtained with a TRITC-Con A/FITC-dextran mass ratio of 500:5 micrograms/mL PEG. Fluorescent response was linear up to 600 mg/dL. At higher concentrations, the response saturated due to the displacement of the majority of the FITC-dextran and to concentration quenching by free FITC-dextran. Dynamic fluorescent change upon glucose addition was approximately 10 min for a glucose concentration step change from 0 to 200 mg/dL.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bradford, M. M. (1976) · Analytical Biochemistry · doi:10.1016/0003-2697(76)90527-3 · Cited by 255,302
Park, G. S. (1975) · Polymer · doi:10.1016/0032-3861(75)90130-5 · Cited by 14,967
Handbook of fluorescent probes and research chemicals
Haugland, R. P. (1996) · Medical Entomology and Zoology · Cited by 2,793
Handbook of plant lectins : properties and biomedical applications
Damme, E. J. M. V. (1998) · Cited by 313
Photopolymerized hydrogel materials for drug delivery applications
West, J. L., & Hubbell, J. A. (1995) · Reactive Polymers · doi:10.1016/0923-1137(94)00096-n · Cited by 244
Optimization of photopolymerized bioerodible hydrogel properties for adhesion prevention
Sawhney, A. S., Pathak, C. P., van Rensburg, J. J., Dunn, R. C., & Hubbell, J. A. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820280710 · Cited by 197
Rapid photopolymerization of immunoprotective gels in contact with cells and tissue
Pathak, C. P., Sawhney, A. S., & Hubbell, J. A. (1992) · Journal of the American Chemical Society · doi:10.1021/ja00047a065 · Cited by 183
Fiber-optic biosensors based on fluorescence energy transfer
Meadows, D. L. (1988) · Talanta · doi:10.1016/0039-9140(88)80053-5 · Cited by 127
Sirkar, K., & Pishko, M. V. (1998) · Analytical Chemistry · doi:10.1021/ac971236x · Cited by 102
Self-citationOptical assay for glucose based on the luminescnence decay time of the long wavelength dye Cy5™
Tolosa, L. M., Malak, H. M., Raob, G., & Lakowicz, J. R. (1997) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(97)00275-x · Cited by 96
Optical sensing of glucose using phase-modulation fluorimetry
Lakowicz, J. R., & Maliwal, B. P. (1993) · Analytica Chimica Acta · doi:10.1016/0003-2670(93)80563-z · Cited by 96
Ballerstädt, R., & Schultz, J. S. (1997) · Analytica Chimica Acta · doi:10.1016/s0003-2670(97)00042-1 · Cited by 89
Cited by
Photopolymerizable hydrogels for tissue engineering applications
Nguyen, K. T., & West, J. L. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00175-8 · Cited by 1,669
Sapsford, K. E., Berti, L., & Medintz, I. L. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200503873 · Cited by 1,561
Borisov, S. M., & Wolfbeis, O. S. (2008) · Chemical Reviews · doi:10.1021/cr068105t · Cited by 1,018
3D printing of hydrogels: Rational design strategies and emerging biomedical applications
Li, J., Wu, C., Chu, P. K., & Gelinsky, M. (2020) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2020.100543 · Cited by 862
Glucose Sensing for Diabetes Monitoring: Recent Developments
Bruen, D., Delaney, C., Florea, L., & Diamond, D. (2017) · Sensors · doi:10.3390/s17081866 · Cited by 777
Metadata
- Authors
- Russell, R. J., Pishko, M. V., Gefrides, C. C., McShane, M. J., & Coté, G. L.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-06-10
- Volume
- 71
- Issue
- 15
- Pages
- 3126-3132
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1975243918
- Cited by
- 353
- References
- 12
- FWCI
- 3.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.