The DOI matches its Crossref record.
Precipitation of an Insoluble Product on Enzyme Monolayer Electrodes for Biosensor Applications: Characterization by Faradaic Impedance Spectroscopy, Cyclic Voltammetry, and Microgravimetric Quartz Crystal Microbalance Analyses
Abstract
Precipitation of an insoluble, insulating product on monolayer-functionalized electrodes enables the development of new electrochemical biosensors. Faradaic impedance spectroscopy and cyclic voltammetry are used to probe the electron-transfer resistance at the conductive support upon the accumulation of the insoluble product on the electrode surface. Similarly, microgravimetric quartz crystal microbalance, QCM, analyses were used to assay the formation of the precipitate on the electrode. A horseradish peroxidase, HRP, monolayer electrode is used to analyze H2O2 via the biocatalyzed oxidation of 4-chloro-1-naphthol (1) and the precipitation of the insoluble product (2). A bienzyme-layered electrode consisting of HRP and glucose oxidase, GOx, is used to sense glucose. Biocatalyzed oxidation of glucose by O2, in the presence of GOx, yields H2O2, and the generated hydrogen peroxide effects the formation of the insoluble product (2) in the presence of HRP. The insoluble product accumulated on the electrode, and the extent of the resulting electron-transfer resistance, correlated with the amounts of H2O2 or glucose, and appropriate calibration curves are extracted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Katz, E., & Willner, I. (2003) · Electroanalysis · doi:10.1002/elan.200390114 · Cited by 1,351
Self-citationMarx, K. A. (2003) · Biomacromolecules · doi:10.1021/bm020116i · Cited by 1,143
Detection of single-base DNA mutations by enzyme-amplified electronic transduction
Patolsky, F., Lichtenstein, A., & Willner, I. (2001) · Nature Biotechnology · doi:10.1038/85704 · Cited by 368
Self-citationMicrofabricated Reference Electrodes and their Biosensing Applications
Shinwari, M. W., Zhitomirsky, D., Deen, I. A., Selvaganapathy, P. R., Deen, M. J., & Landheer, D. (2010) · Sensors · doi:10.3390/s100301679 · Cited by 333
Zhang, S., Wang, N., Yu, H., Niu, Y., & Sun, C. (2005) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2004.12.002 · Cited by 317
Status of biomolecular recognition using electrochemical techniques
Sadik, O. A., Aluoch, A. O., & Zhou, A. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.10.003 · Cited by 315
Impedance-based detection of DNA sequences using a silicon transducer with PNA as the probe layer
Macanovic, A. (2004) · Nucleic Acids Research · doi:10.1093/nar/gnh003 · Cited by 309
Label-Free Electrochemical Detection for Aptamer-Based Array Electrodes
Xu, D., Xu, D., Yu, X., Liu, Z., He, W., & Ma, Z. (2005) · Analytical Chemistry · doi:10.1021/ac050192m · Cited by 304
Reusable Impedimetric Aptasensor
Radi, A.-E., Acero Sánchez, J. L., Baldrich, E., & O'Sullivan, C. K. (2005) · Analytical Chemistry · doi:10.1021/ac0505775 · Cited by 266
Metadata
- Authors
- Patolsky, F., Zayats, M., Katz, E., & Willner, I.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-06-22
- Volume
- 71
- Issue
- 15
- Pages
- 3171-3180
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2064991281
- Cited by
- 234
- References
- 0
- FWCI
- 14.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.