The DOI matches its Crossref record.
The Dominance of Arginine-Containing Peptides in MALDI-Derived Tryptic Mass Fingerprints of Proteins
Abstract
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is a powerful tool for mass finger-printing of peptide mixtures obtained after enzymatic ingel digestion of proteins separated by two-dimensional electrophoresis (2-DE). In the course of a proteome analysis of mycobacteria using mass spectrometric identification, it was found that 94% of the most intense MALDI-MS peaks denote peptides bearing arginine at the C-terminal end. The effect was demonstrated to be equally prominent using an equimolar mixture of the synthetic peptides known to be present in the tryptic digest of the mycobacterial 35 kDa antigen ("synthetic mass map"). In addition, several binary mixtures of synthetic peptides differing exclusively at the C terminus (Arg or Lys) were examined to rationalize the higher sensitivity toward arginine-containing peptides. The extent of the effect described depends on the matrix used and may facilitate a more reliable assignment of mass fingerprint data to protein sequences in databases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
MALDI‐TOF mass spectrometry of bacteria*
Lay, J. O. (2001) · Mass Spectrometry Reviews · doi:10.1002/mas.10003 · Cited by 507
Proteomics of Integral Membrane ProteinsTheory and Application
Speers, A. E., & Wu, C. C. (2007) · Chemical Reviews · doi:10.1021/cr068286z · Cited by 325
Metadata
- Authors
- Krause, E., Wenschuh, H., & Jungblut, P. R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-08-28
- Volume
- 71
- Issue
- 19
- Pages
- 4160-4165
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2025177545
- Cited by
- 287
- References
- 0
- FWCI
- 8.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.