CoChat

Identification of Polar Toxicants in Industrial Wastewaters Using Toxicity-Based Fractionation with Liquid Chromatography/Mass Spectrometry

Castillo, Montserrat, Barceló, Damià · 1999 · Analytical Chemistry
Cited by 73

The DOI matches its Crossref record.

Abstract

An efficient and novel method for the identification of toxic compounds in industrial wastewater was developed. In the first step, the samples collected were tested for toxicity using the recently developed ToxAlert 10 system based upon luminescence inhibition of freeze-dried Vibrio fischeri. In the second step, sequential solid-phase extraction (SSPE) and liquid chromatography/mass spectrometry (LC/MS) for compound identification were employed to isolate and identify compounds in the waters. Average recoveries ranging from 72 to 95% were obtained using the SSPE methodology for ubiquitous analytes such as poly(ethylene glycol)s, nonylphenol and alcohol polyethoxylates, phenols, linear alkylbenzenesulfonates, and benzene- and naphthalenesulfonates. In the third step, all the extracts obtained after SSPE followed by LC/MS identification were tested again with the ToxAlert system. The procedure was applied to influent and effluent samples of a sewage treatment plant (STP) and to a raw tannery effluent that constitutes the main type of influent in the receiving waters of the STP. This method has shown that, despite the complexity of the untreated tannery wastewaters with an average total organic carbon (TOC) value of 1960 mg of C/L, the biological treatment of the STP eliminates compounds that inhibit luminiscence of V. fischeri. In the final step, the chemical toxicity of the tentatively identified chemicals was tested to identify the toxicants in the waters. Comparison of the toxicities of the sample, the extracts, and individual components has shown that diverse classes of pollutants were responsible for toxicity, as all fractions of toxic samples gave significant bioluminescence inhibition values. Toxicity of the two intermediate-polarity SSPE fractions was attributed to alcohol ethoxylates, nonylphenol ethoxylates, bis(2-ethylhexyl)phthalate, and linear alkylbenzenesulfonates. In the most nonpolar and most polar fractions, identification of the compounds responsible for toxicity was unclear. By the toxicity-based fractionation, followed by LC/MS methodology, it was feasible to identify between 1.4 and 7.5% of the TOC, thus expanding the number of toxicants identified in these complex wastewaters as compared to those identified by conventional gas chromatography/mass spectrometric (GC/MS) methods. When artificial water samples were reconstituted using similar concentrations of the chemicals detected in the wastewaters, nonsynergetic toxicity effects were observed for all analytes with the exception of 2,6-naphthalenedisulfonate (2,6-NPS), which promoted the bioluminescence inhibition. The toxicity-directed identification was successful for the STP's samples and showed 1400 times higher toxicity for the raw tannery wastewaters as compared to the mixed industrial and domestic wastewaters by applying the Weibull model.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac990364d

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Castillo, M., & Barceló, D.
Venue
Analytical Chemistry
Published
1999-07-30
Volume
71
Issue
17
Pages
3769-3776
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2046301857
Cited by
73
References
0
FWCI
8.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.