The DOI matches its Crossref record.
Microfabricated Capillary Electrophoresis Amino Acid Chirality Analyzer for Extraterrestrial Exploration
Abstract
Chiral separations of fluorescein isothiocyanate-labeled amino acids have been performed on a microfabricated capillary electrophoresis chip to explore the feasibility of using such devices to analyze for extinct or extant life signs in extraterrestrial environments. The test system consists of a folded electrophoresis channel (19.0 cm long x 150 microns wide x 20 microns deep) that was photolithographically fabricated in a 10-cm-diameter glass wafer sandwich, coupled to a laser-excited confocal fluorescence detection apparatus providing subattomole sensitivity. Using a sodium dodecyl sulfate/gamma-cyclodextrin pH 10.0 carbonate electrophoresis buffer and a separation voltage of 550 V/cm at 10 degrees C, baseline resolution was observed for Val, Ala, Glu, and Asp enantiomers and Gly in only 4 min. Enantiomeric ratios were determined for amino acids extracted from the Murchison meteorite, and these values closely matched values determined by HPLC. These results demonstrate the feasibility of using microfabricated lab-on-a-chip systems to analyze extraterrestrial samples for amino acids.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Separation of enantiomers: needs, challenges, perspectives
Maier, N. M., Franco, P., & Lindner, W. (2001) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00532-x · Cited by 1,014
Combinatorial and Evolution-Based Methods in the Creation of Enantioselective Catalysts
Reetz, M. T. (2001) · Angewandte Chemie International Edition · doi:10.1002/1521-3773(20010119)40:2<284::aid-anie284>3.0.co;2-n · Cited by 594
Microfluidic chips for clinical and forensic analysis
Verpoorte, E. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200203)23:5<677::aid-elps677>3.0.co;2-8 · Cited by 526
Grover, W. H., Skelley, A. M., Liu, C. N., Lagally, E. T., & Mathies, R. A. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00468-9 · Cited by 517
Self-citationLab-on-a-chip for drug development
Weigl, B. H., Bardell, R. L., & Cabrera, C. R. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(02)00223-5 · Cited by 481
Extraterrestrial Organic Compounds in Meteorites
Botta, O., & Bada, J. L. (2002) · Surveys in Geophysics · doi:10.1023/a:1020139302770 · Cited by 425
Self-citationDevelopment and evaluation of a microdevice for amino acid biomarker detection and analysis on Mars
Skelley, A. M., Scherer, J. R., Aubrey, A. D., Grover, W. H., Ivester, R. H. C., Ehrenfreund, P., Grunthaner, F. J., Bada, J. L., & Mathies, R. A. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406798102 · Cited by 262
Self-citationSerine Octamers: Cluster Formation, Reactions, and Implications for Biomolecule Homochirality
Nanita, S. C., & Cooks, R. G. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200501328 · Cited by 184
Review Article: Immobilized Molecules Using Biomaterials and Nanobiotechnology
M. M. Elnashar, M. (2010) · Journal of Biomaterials and Nanobiotechnology · doi:10.4236/jbnb.2010.11008 · Cited by 77
Metadata
- Authors
- Hutt, L. D., Glavin, D. P., Bada, J. L., & Mathies, R. A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-08-17
- Volume
- 71
- Issue
- 18
- Pages
- 4000-4006
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1972949590
- Cited by
- 162
- References
- 0
- FWCI
- 15.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.