Abstract
A liquid-junction Ag/AgCl reference electrode was microfabricated. A silver thin-film pattern was covered with a polyimide protecting layer with a 50-μm-wide slit at the center of the pattern, and the AgCl layer was grown from there into the silver layer. A liquid junction was formed with a photocurable hydrophilic polymer. The electrolyte layer was formed by screen-printing a paste containing fine KCl powder. A silicone rubber passivation covered the entire area except for the pad and the end of the junction. The novel thin-film Ag/AgCl element could maintain its expected potential for longer than 30 h in a saturated KCl solution. The completed miniature liquid-junction reference electrode could maintain a stable potential level within ±1 mV for longer than 100 h with the aid of a poly(vinylpyrrolidone) (PVP) matrix in the electrolyte layer. Fluctuation of the potential was less than 0.1 mV at each moment. Dependency on external KCl concentration and pH was shown to be insignificant. The miniature reference electrode was integrated with an iridium oxide pH indicator electrode. No significant difference was observed between the potential obtained with the miniature reference electrode and that obtained with a macroscopic commercial Ag/AgCl electrode, which confirmed that the miniature reference electrode was applicable to one-chip potentiometric sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Wearable Electrochemical Platform for Noninvasive Simultaneous Monitoring of Ca2+ and pH
Nyein, H. Y. Y., Gao, W., Shahpar, Z., Emaminejad, S., Challa, S., Chen, K., Fahad, H. M., Tai, L.-C., Ota, H., Davis, R. W., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b04005 · Cited by 669
Microfabricated Reference Electrodes and their Biosensing Applications
Shinwari, M. W., Zhitomirsky, D., Deen, I. A., Selvaganapathy, P. R., Deen, M. J., & Landheer, D. (2010) · Sensors · doi:10.3390/s100301679 · Cited by 333
Current research activity in biosensors
Nakamura, H., & Karube, I. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-1947-5 · Cited by 299
Self-citation
Metadata
- Authors
- Suzuki, H., Shiroishi, H., Sasaki, S., & Karube, I.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-10-08
- Volume
- 71
- Issue
- 22
- Pages
- 5069-5075
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2042348803
- Cited by
- 162
- References
- 0
- FWCI
- 4.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microfabricated Liquid Junction Ag/AgCl Reference Electrode and Its Application to a One-Chip Potentiometric Sensor. https://app.cochat.ai/papers/10.1021/ac990437t
- The paper
- Suzuki, H., Shiroishi, H., Sasaki, S., & Karube, I. (1999). Microfabricated Liquid Junction Ag/AgCl Reference Electrode and Its Application to a One-Chip Potentiometric Sensor. Analytical Chemistry. https://doi.org/10.1021/ac990437t
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.