The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Millisecond Radiolytic Modification of Peptides by Synchrotron X-rays Identified by Mass Spectrometry
Abstract
Radiolysis of peptide and protein solutions with high-energy X-ray beams induces stable, covalent modifications of amino acid residues that are useful for synchrotron protein footprinting. A series of 5-14 amino acid residue peptides of varied sequences were selected to study their synchrotron radiolysis chemistry. Radiolyzed peptide products were detected within 10 ms of exposure to a white light synchrotron X-ray beam. Mass spectrometry techniques were used to characterize radiolytic modification to amino acids cysteine (Cys), methionine (Met), phenylalanine (Phe), tyrosine (Tyr), tryptophan (Trp), proline (Pro), histidine (His), and leucine (Leu). A reactivity order of Cys, Met >> Phe, Tyr, > Trp > Pro > His, Leu was determined under aerobic reaction conditions from MS/MS analysis of the radiolyzed peptide products. Radiolysis of peptides in 18O-labeled water under aerobic conditions revealed that oxygenated radical species from air and water both contribute to the modification of amino acid side chains. Cysteine and methionine side chains reacted with hydroxyl radicals generated from radiolysis of water as well as molecular oxygen. Phenylalanine and tyrosine residues were modified predominantly by hydroxyl radicals, and the source of modification of proline was exclusively through molecular oxygen.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2‐Oxo‐histidine as a novel biological marker for oxidatively modified proteins
Uchida, K., & Kawakishi, S. (1993) · FEBS Letters · doi:10.1016/0014-5793(93)80632-5 · Cited by 146
Cited by
Hydroxyl Radical-Mediated Modification of Proteins as Probes for Structural Proteomics
Xu, G., & Chance, M. R. (2007) · Chemical Reviews · doi:10.1021/cr0682047 · Cited by 683
Self-citationStudies of biomolecular conformations and conformational dynamics by mass spectrometry
Kaltashov, I. A., & Eyles, S. J. (2002) · Mass Spectrometry Reviews · doi:10.1002/mas.10017 · Cited by 270
Structural waters define a functional channel mediating activation of the GPCR, rhodopsin
Angel, T. E., Gupta, S., Jastrzebska, B., Palczewski, K., & Chance, M. R. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0901074106 · Cited by 203
Self-citationVisualizing Water Molecules in Transmembrane Proteins Using Radiolytic Labeling Methods
Orban, T., Gupta, S., Palczewski, K., & Chance, M. R. (2010) · Biochemistry · doi:10.1021/bi901889t · Cited by 45
Self-citation
Metadata
- Authors
- Maleknia, S. D., Brenowitz, M., & Chance, M. R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-08-11
- Volume
- 71
- Issue
- 18
- Pages
- 3965-3973
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2000390034
- Cited by
- 221
- References
- 1
- FWCI
- 3.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Millisecond Radiolytic Modification of Peptides by Synchrotron X-rays Identified by Mass Spectrometry. https://app.cochat.ai/papers/10.1021/ac990500e
- The paper
- Maleknia, S. D., Brenowitz, M., & Chance, M. R. (1999). Millisecond Radiolytic Modification of Peptides by Synchrotron X-rays Identified by Mass Spectrometry. Analytical Chemistry. https://doi.org/10.1021/ac990500e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.