The DOI matches its Crossref record.
Microfluidic Assays of Acetylcholinesterase Inhibitors
Abstract
A microfabricated device for flow injection analysis and electrophoretic separation of acetylcholinesterase (AChE) inhibitors is described. Solutions of inhibitor, enzyme, substrate, and derivitizing agent were mixed within the channels of the microchip using computer-controlled electrokinetic transport. AChE-catalyzed hydrolysis of acetylthiocholine to thiocholine was measured in an on-chip reaction of thiocholine with coumarinylphenylmaleimide, and the resulting thioether was detected by laser-induced fluorescence. Inhibitors reduced the fluorescence signal and produced a negative peak diagnostic for the type of inhibition. A Gaussian peak was observed for competitive inhibitors, whereas a broad negative peak was observed for irreversible inhibitors. From a microchip assay for tacrine, an inhibition constant, K i, of 1.5 ± 0.2 nM was derived, which compared well with a standard cuvette assay. A flow injection assay of two irreversible inhibitors, carbofuran and eserine, was performed. With a 5-min stopped-flow reaction time, a detection limit of 10 nM carbofuran was obtained. As a potential multiplex screening device, a mixture of four cationic inhibitors, tacrine, edrophonium, and tetramethyl- and tetraethylammonium chloride, was separated and detected within 70 s.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wang, M., Zhang, G., Zhang, D., Zhu, D., & Tang, B. Z. (2010) · Journal of Materials Chemistry · doi:10.1039/b921610c · Cited by 852
Microfluidic chips for clinical and forensic analysis
Verpoorte, E. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200203)23:5<677::aid-elps677>3.0.co;2-8 · Cited by 526
High-throughput and ultra-high-throughput screening: solution- and cell-based approaches
Sundberg, S. (2000) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(99)00051-8 · Cited by 455
Microfluidic Devices for the High-Throughput Chemical Analysis of Cells
McClain, M. A., Culbertson, C. T., Jacobson, S. C., Allbritton, N. L., Sims, C. E., & Ramsey, J. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346510 · Cited by 383
Self-citationPlanar chip device for PCR and hybridization with surface acoustic wave pump
Guttenberg, Z., Müller, H., Habermüller, H., Geisbauer, A., Pipper, J., Felbel, J., Kielpinski, M., Scriba, J., & Wixforth, A. (2005) · Lab Chip · doi:10.1039/b412712a · Cited by 349
Metadata
- Authors
- Hadd, A. G., Jacobson, S. C., & Ramsey, J. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-10-15
- Volume
- 71
- Issue
- 22
- Pages
- 5206-5212
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2012555890
- Cited by
- 193
- References
- 0
- FWCI
- 9.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microfluidic Assays of Acetylcholinesterase Inhibitors. https://app.cochat.ai/papers/10.1021/ac990591f
- The paper
- Hadd, A. G., Jacobson, S. C., & Ramsey, J. M. (1999). Microfluidic Assays of Acetylcholinesterase Inhibitors. Analytical Chemistry. https://doi.org/10.1021/ac990591f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.