The DOI matches its Crossref record.
Automated Identification of Amino Acid Sequence Variations in Proteins by HPLC/Microspray Tandem Mass Spectrometry
Abstract
Amino acid sequence variations resulting from single-nucleotide polymorphisms (SNPs) were identified using a novel mass spectrometric method. This method obtains 99+% protein sequence coverage for human hemoglobin in a single LC-microspray tandem mass spectrometry (microLC-MS/MS) experiment. Tandem mass spectrometry data was analyzed using a modified version of the computer program SEQUEST to identify the sequence variations. Conditions of sample preparation, chromatographic separation, and data collection were optimized to correctly identify amino acid changes in six variants of human hemoglobin (Hb C, Hb E, Hb D-Los Angeles, Hb G-Philadelphia, Hb Hope, and Hb S). Hemoglobin proteins were isolated and purified, dehemed, (S)-carboxyami-domethylated, and then subjected to a combination proteolytic digestion to obtain a complex peptide mixture with multiple overlaps in sequence. Reversed-phase chromatographic separation of peptides was achieved on-line with MS utilizing a robust fritless microelectrospray interface. Tandem mass spectrometry was performed on an ion trap mass spectrometer using automated data-dependent MS/MS procedures. Tandem mass spectra were collected from the five most abundant ions in each scan using dynamic and isotopic exclusion to minimize redundancy. The spectra were analyzed by a version of the SEQUEST algorithm modified to identify amino acid substations resulting from SNPs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Self-citationShotgun identification of protein modifications from protein complexes and lens tissue
MacCoss, M. J., McDonald, W. H., Saraf, A., Sadygov, R., Clark, J. M., Tasto, J. J., Gould, K. L., Wolters, D., Washburn, M., Weiss, A., et al. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.122231399 · Cited by 593
Self-citationWells, L., Vosseller, K., Cole, R. N., Cronshaw, J. M., Matunis, M. J., & Hart, G. W. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m200048-mcp200 · Cited by 420
Wiśniewski, J. R., & Mann, M. (2012) · Analytical Chemistry · doi:10.1021/ac300006b · Cited by 299
Ting, Y. S., Egertson, J. D., Payne, S. H., Kim, S., MacLean, B., Käll, L., Aebersold, R., Smith, R. D., Noble, W. S., & MacCoss, M. J. (2015) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o114.047035 · Cited by 175
Metadata
- Authors
- Gatlin, C. L., Eng, J. K., Cross, S. T., Detter, J. C., & Yates, J. R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-01-14
- Volume
- 72
- Issue
- 4
- Pages
- 757-763
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2036102880
- Cited by
- 233
- References
- 0
- FWCI
- 11.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated Identification of Amino Acid Sequence Variations in Proteins by HPLC/Microspray Tandem Mass Spectrometry. https://app.cochat.ai/papers/10.1021/ac991025n
- The paper
- Gatlin, C. L., Eng, J. K., Cross, S. T., Detter, J. C., & Yates, J. R. (2000). Automated Identification of Amino Acid Sequence Variations in Proteins by HPLC/Microspray Tandem Mass Spectrometry. Analytical Chemistry. https://doi.org/10.1021/ac991025n
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.