The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Design Principles, Sensing Mechanisms, and Applications of Highly Specific Fluorescent Probes for HOCl/OCl–
Abstract
Conspectus Hypochlorous acid/hypochlorite (HOCl/OCl – ), one of the most important reactive oxygen species (ROS), plays vital roles in various physiological and pathological processes. At normal concentrations, OCl – acts as part of an immune defense system by destroying invasive bacteria and pathogens. However, nonproperly located or excessive amounts of OCl – are related to many diseases, including cancers. Thus, detection of OCl – has great importance. Owing to their high sensitivities, selectivities, fast response times, technical simplicities, and high temporal and spatial resolution, fluorescent probes are powerful tools for in vitro and in vivo sensing of target substances. This Account focuses on the development of new chemosensors for detection of OCl –, which operate by undergoing a chemical reaction with this ROS in conjunction with a change in emission properties. As part of the presentation, we first introduce several important factors that need to be considered in the design of fluorescent chemosensors for OCl –, including fluorophores, reaction groups, cosolvents, and buffers. Discussion here revolves around the need to select fluorophores that resist oxidation by OCl – . As well, attention is given to the sensitivities and selectivities of groups in the sensors that react with OCl – to trigger a fluorescence response. Moreover, well-known reaction groups, which react with highly reactive ROS (hROS), have been redesigned to be specific for OCl – . In addition, it is pointed out that several cosolvents and buffers such as DMSO and HEPES are not suitable for use in systems for the detection of OCl – because they are readily oxidized by this ROS. We further discuss recent investigations carried out by us and others aimed at the development of fluorescent probes for in vitro and in vivo detection of OCl – . These efforts led to the new “dual lock” strategy for designing OCl – chemosensors as well as several new specific reaction groups such as imidazoline-2-thiones and imidazoline-2-boranes. Probes created using this strategy and the new reacting groups have been successfully applied to imaging exogenous and endogenous OCl – in live cells and/or tissues. The design concepts and strategies emanating from our studies of fluorescent OCl – probes have provided insight into the general field of fluorescent probes. Despite the progress made thus far, challenges still remain in developing and applying fluorescent OCl – probes. For example, more highly specific and sensitive fluorescent OCl – probes are still in great demand for studies of the biological roles played by OCl – . Thus, interdisciplinary collaborations of chemists, biologists, and medical practitioners are needed to drive future developments of OCl – probes for disease diagnosis and drug screening.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Myeloperoxidase: friend and foe
Klebanoff, S. J. (2005) · Journal of Leukocyte Biology · doi:10.1189/jlb.1204697 · Cited by 2,282
Fluorescent chemosensors: the past, present and future
Wu, D., Sedgwick, A. C., Gunnlaugsson, T., Akkaya, E. U., Yoon, J., & James, T. D. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00240h · Cited by 2,002
Self-citationChemistry and biology of reactive oxygen species in signaling or stress responses
Dickinson, B. C., & Chang, C. J. (2011) · Nature Chemical Biology · doi:10.1038/nchembio.607 · Cited by 1,821
Bioprobes Based on AIE Fluorogens
Ding, D., Li, K., Liu, B., & Tang, B. Z. (2013) · Accounts of Chemical Research · doi:10.1021/ar3003464 · Cited by 1,817
Recent progress in the development of near-infrared fluorescent probes for bioimaging applications
Guo, Z., Park, S., Yoon, J., & Shin, I. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60271k · Cited by 1,801
Self-citationSmall molecule-based ratiometric fluorescence probes for cations, anions, and biomolecules
Lee, M. H., Kim, J. S., & Sessler, J. L. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00280f · Cited by 1,642
Excited-state intramolecular proton-transfer (ESIPT) based fluorescence sensors and imaging agents
Sedgwick, A. C., Wu, L., Han, H.-H., Bull, S. D., He, X.-P., James, T. D., Sessler, J. L., Tang, B. Z., Tian, H., & Yoon, J. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00185e · Cited by 1,569
Self-citationSetsukinai, K.-I., Urano, Y., Kakinuma, K., Majima, H. J., & Nagano, T. (2003) · Journal of Biological Chemistry · doi:10.1074/jbc.m209264200 · Cited by 1,301
Chen, X., Wang, F., Hyun, J. Y., Wei, T., Qiang, J., Ren, X., Shin, I., & Yoon, J. (2016) · Chem. Soc. Rev. · doi:10.1039/c6cs00192k · Cited by 1,166
Self-citationRecent Development of Chemosensors Based on Cyanine Platforms
Sun, W., Guo, S., Hu, C., Fan, J., & Peng, X. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00001 · Cited by 1,109
Cited by
Li, H., Kim, H., Xu, F., Han, J., Yao, Q., Wang, J., Pu, K., Peng, X., & Yoon, J. (2022) · Chemical Society Reviews · doi:10.1039/d1cs00307k · Cited by 509
Self-citationActivity‐Based NIR Enzyme Fluorescent Probes for the Diagnosis of Tumors and Image‐Guided Surgery
Li, H., Kim, D., Yao, Q., Ge, H., Chung, J., Fan, J., Wang, J., Peng, X., & Yoon, J. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202009796 · Cited by 363
Self-citationSargazi, S., Fatima, I., Hassan Kiani, M., Mohammadzadeh, V., Arshad, R., Bilal, M., Rahdar, A., Díez-Pascual, A. M., & Behzadmehr, R. (2022) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2022.02.137 · Cited by 329
Kwon, N., Kim, D., Swamy, K. M. K., & Yoon, J. (2021) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2020.213581 · Cited by 301
Self-citationFluorescent probes for the detection of disease-associated biomarkers
Dou, W.-T., Han, H.-H., Sedgwick, A. C., Zhu, G.-B., Zang, Y., Yang, X.-R., Yoon, J., James, T. D., Li, J., & He, X.-P. (2022) · Science Bulletin · doi:10.1016/j.scib.2022.01.014 · Cited by 266
Self-citation
Metadata
- Authors
- Wu, D., Chen, L., Xu, Q., Chen, X., & Yoon, J.
- Venue
- Accounts of Chemical Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-07-18
- Volume
- 52
- Issue
- 8
- Pages
- 2158-2168
- ISSN
- 0001-4842 (ISSN-L)
- 1520-4898
- OpenAlex
- W2963200837
- Cited by
- 387
- References
- 56
- FWCI
- 20.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design Principles, Sensing Mechanisms, and Applications of Highly Specific Fluorescent Probes for HOCl/OCl–. https://app.cochat.ai/papers/10.1021/acs.accounts.9b00307
- The paper
- Wu, D., Chen, L., Xu, Q., Chen, X., & Yoon, J. (2019). Design Principles, Sensing Mechanisms, and Applications of Highly Specific Fluorescent Probes for HOCl/OCl–. Accounts of Chemical Research. https://doi.org/10.1021/acs.accounts.9b00307
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.