Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 176

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Exploring the Trans-Cleavage Activity of CRISPR/Cas12a on Gold Nanoparticles for Stable and Sensitive Biosensing

Fu, Xiaoyi, Shi, Yuyan, Peng, Fangqi, Zhou, Min, Yin, Yao, Tan, Yin, Chen, Mei, Yin, Xia, Ke, Guoliang, Zhang, Xiao-Bing·2021·Analytical Chemistry

Abstract

Taking advantage of the excellent trans-cleavage activity, CRISPR-based diagnostics (CRISPR-Dx) has shown great promise in molecular diagnostics. However, the single-stranded DNA reporter of the current CRISPR-Dx suffers from poor stability and limited sensitivity, which make their application in complex biological environments difficult. Herein, we, for the first time, explore the trans-cleavage activity of CRISPR/Cas12a toward the substrate on gold nanoparticles and apply the new phenomenon to develop a spherical nucleic acid (SNA) reporter for stable and sensitive CRISPR-Dx biosensing. By anchoring the DNA substrate on gold nanoparticles, we discovered different trans-cleavage activities of different types of the Cas12a system (e.g., LbCas12a and AsCas12a) on a nanoparticle surface. The further study suggests that the trans-cleavage activity of LbCas12a on the nanoparticle surface is highly dependent on the density and length of DNA strands. Based on these interesting discoveries, we furthermore develop SNA reporter-based fluorescent CRISPR-Dx for stable and sensitive biosensing application. Compared to traditional ssDNA reporters, the SNA reporter exhibits improved stability, which enables the stable application in a complex serum environment. In addition, the SNA reporter system with tunable density exhibits high sensitivity with a detection limit of 10 fM, which is about 2 orders of magnitude lower than that of the ssDNA reporter system. Finally, the practical application of SNA reporter-based CRISPR-Dx in clinical serum was successfully achieved. These results indicate their significant potential in future research on biology science and medical diagnoses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.1c00027

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 176

Metadata

Authors
Fu, X., Shi, Y., Peng, F., Zhou, M., Yin, Y., Tan, Y., Chen, M., Yin, X., Ke, G., & Zhang, X.-B.
Venue
Analytical Chemistry
Published
2021-03-11
Volume
93
Issue
11
Pages
4967-4974
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W3133897829
Cited by
176
References
1
FWCI
6.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Exploring the Trans-Cleavage Activity of CRISPR/Cas12a on Gold Nanoparticles for Stable and Sensitive Biosensing. https://app.cochat.ai/papers/10.1021/acs.analchem.1c00027
The paper
Fu, X., Shi, Y., Peng, F., Zhou, M., Yin, Y., Tan, Y., Chen, M., Yin, X., Ke, G., & Zhang, X.-B. (2021). Exploring the Trans-Cleavage Activity of CRISPR/Cas12a on Gold Nanoparticles for Stable and Sensitive Biosensing. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.1c00027

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.