Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 159

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Enzyme Kinetics and Detector Sensitivity Determine Limits of Detection of Amplification-Free CRISPR-Cas12 and CRISPR-Cas13 Diagnostics

Huyke, Diego A., Ramachandran, Ashwin, Bashkirov, Vladimir I., Kotseroglou, Efthalia K., Kotseroglou, Theofilos, Santiago, Juan G.·2022·Analytical Chemistry

Abstract

Interest in CRISPR-Cas12 and CRISPR-Cas13 detection continues to increase as these detection schemes enable the specific recognition of nucleic acids. The fundamental sensitivity limits of these schemes (and their applicability in amplification-free assays) are governed by kinetic rates. However, these kinetic rates remain poorly understood, and their reporting has been inconsistent. We quantify kinetic parameters for several enzymes (LbCas12a, AsCas12a, AapCas12b, LwaCas13a, and LbuCas13a) and their corresponding limits of detection (LoD). Collectively, we present quantification of enzyme kinetics for 14 guide RNAs (gRNAs) and nucleic acid targets for a total of 50 sets of kinetic rate parameters and 25 LoDs. We validate the self-consistency of our measurements by comparing trends and limiting behaviors with a Michaelis–Menten trans -cleavage reaction kinetics model. For our assay conditions, activated Cas12 and Cas13 enzymes exhibit trans -cleavage catalytic efficiencies between order 10 5 and 10 6 M –1 s –1 . For assays that use fluorescent reporter molecules (ssDNA and ssRNA) for target detection, the kinetic rates at the current assay conditions result in an amplification-free LoD in the picomolar range. The results suggest that successful detection of target requires cleavage (by an activated CRISPR enzyme) of the order of at least 0.1% of the fluorescent reporter molecules. This fraction of reporters cleaved is required to differentiate the signal from the background, and we hypothesize that this required fraction is largely independent of the detection method (e.g., endpoint vs reaction velocity) and detector sensitivity. Our results demonstrate the fundamental nature by which kinetic rates and background signal limit LoDs and thus highlight areas of improvement for the emerging field of CRISPR diagnostics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.2c01670

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 159

Metadata

Authors
Huyke, D. A., Ramachandran, A., Bashkirov, V. I., Kotseroglou, E. K., Kotseroglou, T., & Santiago, J. G.
Venue
Analytical Chemistry
Published
2022-06-27
Volume
94
Issue
27
Pages
9826-9834
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W4283586979
Cited by
159
References
1
FWCI
7.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Enzyme Kinetics and Detector Sensitivity Determine Limits of Detection of Amplification-Free CRISPR-Cas12 and CRISPR-Cas13 Diagnostics. https://app.cochat.ai/papers/10.1021/acs.analchem.2c01670
The paper
Huyke, D. A., Ramachandran, A., Bashkirov, V. I., Kotseroglou, E. K., Kotseroglou, T., & Santiago, J. G. (2022). Enzyme Kinetics and Detector Sensitivity Determine Limits of Detection of Amplification-Free CRISPR-Cas12 and CRISPR-Cas13 Diagnostics. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.2c01670

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.