The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Enhancing the Separation and Quantification of Perfluoroalkyl Substances Using Polymeric Ionic Liquid Sorbents in Thin Film Microextraction
Abstract
The preconcentration and isolation of per- and polyfluoroalkyl substances (PFAS) remain challenging due to their varying chain lengths and diverse headgroup chemical functionalities. These substances are persistent and occur in the environment at low parts-per-trillion concentration levels, necessitating the use of efficient and selective sorbents that can enhance their preconcentration from the targeted sample prior to instrumental analysis. This study, for the first time, evaluates the use of a polymeric ionic liquid (PIL) consisting of 1-(9-carboxy-nonyl)-3-vinylimidazolium bromide [C 9 COOHVim + ] [Br – ] ionic liquid (IL) monomer and 1,12-di(3-vinylimidazolium)dodecane bromide ([C 12 (Vim + ) 2 ]2[Br – ]) IL cross-linker for the simultaneous separation and preconcentration of 15 anionic PFAS. The PIL was immobilized on a thin film microextraction device to improve preconcentration, extraction, and desorption kinetics. The addition of competing anions to the desorption solution was critical to ensure the quantitative desorption of the anionic PFAS by an ion exchange mechanism. Partition coefficient calculations revealed a balanced extraction coverage for short- and long-chain PFAS in ultrapure water, while in solutions at high ionic strength, short-chain PFAS tend to display less affinity for the sorbent compared to long-chain PFAS. Kinetic studies showed that less hydrophobic PFAS (perfluorobutanoic acid (PFBA)–perfluorohexanoic acid (PFHxA)) reached equilibrium faster and the extraction followed a pseudo-second order model with r 2 values up to 0.9874. The applicability of the PIL-thin film microextraction (TFME) device for quantitative analysis was demonstrated by a calibration curve in a concentration range from 1 ng L –1 to 2500 ng L –1, which showed good accuracy (70–130%), precision (<20%), and limits of quantification from 1 ng L –1 to 50 ng L –1 .
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adsorption behavior and mechanism of perfluorinated compounds on various adsorbents—A review
Du, Z., Deng, S., Bei, Y., Huang, Q., Wang, B., Huang, J., & Yu, G. (2014) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2014.04.038 · Cited by 1,236
Sorption of perfluorinated compounds from contaminated water to activated carbon
Hansen, M. C., Børresen, M. H., Schlabach, M., & Cornelissen, G. (2010) · Journal of Soils and Sediments · doi:10.1007/s11368-009-0172-z · Cited by 175
Flagged first, then by citations
Research works printed but not linked: 31
- 10.1016/j.talanta.2018.06.011 · DOI
- 10.1016/j.chroma.2009.08.012 · DOI · Paper page
- 10.1002/jssc.201000855 · DOI
- 10.1039/C9AY02073J · DOI
- 10.1021/ac034506m · DOI
- 10.1016/j.aca.2016.06.014 · DOI
- 10.1016/j.chroma.2008.03.063 · DOI
- 10.1021/jp212202b · DOI
- 10.1016/j.jes.2022.08.025 · DOI
- 10.1016/j.envpol.2020.115330 · DOI
- 10.1289/EHP6837 · DOI · Paper page
- 10.1016/j.trac.2023.117062 · DOI
- 10.1016/j.ceja.2021.100135 · DOI
- 10.1016/j.chroma.2014.04.098 · DOI
- 10.1021/acs.analchem.4c01683 · DOI
- 10.1021/acs.analchem.1c05380 · DOI
- 10.1016/j.scitotenv.2021.148821 · DOI
- 10.1136/bmj.333.7574.873-a · DOI
- 10.1016/j.aca.2023.341206 · DOI
- 10.1016/j.chroma.2021.462335 · DOI
- 10.3390/molecules26237159 · DOI
- 10.3390/colloids6030041 · DOI
- 10.1021/acs.estlett.1c00762 · DOI
- 10.1016/j.scitotenv.2023.166568 · DOI
- 10.1016/j.seppur.2024.127851 · DOI
- 10.1016/j.jhazmat.2023.132378 · DOI · Paper page
- 10.1021/acs.langmuir.2c02798 · DOI
- 10.3390/w12113287 · DOI
- 10.1038/s41598-023-39241-z · DOI
- 10.1016/j.chroma.2022.463636 · DOI
- 10.1016/j.chroma.2004.08.163 · DOI
Metadata
- Authors
- Olomukoro, A. A., Eitzmann, D. R., Anderson, J. L., & Gionfriddo, E.
- Affiliations
- University at Buffalo, State University of New York (US)
- Iowa State University (US)
- Corresponding author
- Gionfriddo, Emanuela
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2025-04-07
- Volume
- 97
- Issue
- 14
- Pages
- 7610-7615
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W4409234741
- Cited by
- 6
- References
- 2
- Citations by year
- 2026: 5 · 2025: 1
- FWCI
- 1.58
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Division of Chemistry (2203891, 2432184)
- Iowa State University
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Environmental Science › Environmental Chemistry › Per- and polyfluoroalkyl substances research
- Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Ionic liquids properties and applications
- Keywords
- per- and polyfluoroalkyl substances, PFAS, poly(ionic liquids), thin film microextraction, preconcentration, ion exchange, partition coefficient, extraction kinetics, pseudo-second-order kinetics, competing anions, desorption, chain length effects, perfluorobutanoic acid, perfluorohexanoic acid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review