Influence of Next-Generation Sequencing and Storage Conditions on miRNA Patterns Generated from PAXgene Blood
Abstract
Whole blood derived miRNA signatures determined by Next-Generation Sequencing (NGS) offer themselves as future minimally invasive biomarkers for various human diseases. The PAXgene system is a commonly used blood storage system for miRNA analysis. Central to all miRNA analyses that aim to identify disease specific miRNA signatures, is the question of stability and variability of the miRNA profiles that are generated by NGS. We characterized the influence of five different conditions on the genome wide miRNA expression pattern of human blood isolated in PAXgene RNA tubes. In detail, we analyzed 15 miRNomes from three individuals. The blood was subjected to different numbers of freeze/thaw cycles and analyzed for the influence of storage at -80 or 8 °C. We also determined the influence of blood collection and NGS preparations on the miRNA pattern isolated from a single individual, which has been sequenced 10 times. Here, five PAXGene tubes were consecutively collected that have been split in two replicates, representing two experimental batches. All samples were analyzed by Illumina NGS. For each sample, approximately 20 million NGS reads have been generated. Hierarchical clustering and Principal Component Analysis (PCA) showed an influence of the different conditions on the miRNA patterns. The effects of the different conditions on miRNA abundance are, however, smaller than the differences that are due to interindividual variability. We also found evidence for an influence of…
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Previous studies observed a substantial bias introduced in NGS data by sample preparation of blood samples (10).
“In previous studies, we observed a substantial bias introduced in Next Generation Sequencing (NGS) data by sample preparation of blood samples (10).”
From Distribution of miRNA expression across human tissues (2016) · cites this paper as [10]
Cited by
Sorted by citations
Distribution of miRNA expression across human tissues
Ludwig, N., Leidinger, P., Becker, K., Backes, C., Fehlmann, T., Pallasch, C., Rheinheimer, S., Meder, B., Stähler, C., Meese, E., et al. (2016) · Nucleic Acids Research · doi:10.1093/nar/gkw116 · Cited by 968 · see citing works
Self-citation
- Authors
- Backes, C., Leidinger, P., Altmann, G., Wuerstle, M., Meder, B., Galata, V., Mueller, S. C., Sickert, D., Stähler, C., Meese, E., & Keller, A.
- Affiliations
- Chair for Clinical Bioinformatics, Saarland University, 66123 Saarbrücken, Germany
- Institute of Human Genetics, Saarland University, D-66424 Homburg, Germany
- Siemens AG, 80333 Munich, Germany
- Internal Medicine II, University Hospital Heidelberg, 69120 Heidelberg, Germany
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-08-10
- Volume
- 87
- Issue
- 17
- Pages
- 8910-8916
- ISSN
- 0003-2700
- 1520-6882
- Cited by
- 24
- References
- 0
- Language
- en
- Funders
- Seventh Framework Programme
- Siemens
- Universit?t des Saarlandes
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review